Estimating Hemodynamic Responses to the Wingate Test Using Thoracic Impedance.
نویسندگان
چکیده
UNLABELLED Techniques including direct Fick and Doppler echocardiography are frequently used to assess hemodynamic responses to exercise. Thoracic impedance has been shown to be a noninvasive alternative to these methods for assessing these responses during graded exercise to exhaustion, yet its feasibility during supramaximal bouts of exercise is relatively unknown. We used thoracic impedance to estimate stroke volume (SV) and cardiac output (CO) during the Wingate test (WAnT) and compared these values to those from graded exercise testing (GXT). Active men (n = 9) and women (n = 7) (mean age = 24.8 ± 5.9 yr) completed two Wingate tests and two graded exercise tests on a cycle ergometer. During exercise, heart rate (HR), SV, and CO were continuously estimated using thoracic impedance. Repeated measures analysis of variance was used to identify potential differences in hemodynamic responses across protocols. RESULTS Maximal SV (138.6 ± 37.4 mL vs. 135.6 ± 26.9 mL) and CO (24.5 ± 6.1 L·min(-1) vs. 23.7 ± 5.1 L·min(-1)) were similar (p > 0.05) between repeated Wingate tests. Mean maximal HR was higher (p < 0.01) for GXT (185 ± 7 b·min(-1)) versus WAnT (177 ± 11 b·min(-1)), and mean SV was higher in response to WAnT (137.1 ± 32.1 mL) versus GXT (123.0 ± 32.0 mL), leading to similar maximal cardiac output between WAnT and GXT (23.9 ± 5.6 L·min(-1) vs. 22.5 ± 6.0 L·min(-1)). Our data show no difference in hemodynamic responses in response to repeated administrations of the Wingate test. In addition, the Wingate test elicits similar cardiac output compared to progressive cycling to VO2max. Key pointsMeasurement of cardiac output (CO), the rate of oxygen transport delivered by the heart to skeletal muscle, is not widely-employed in Exercise Physiology due to the level of difficulty and invasiveness characteristic of most techniques used to measure this variable.Nevertheless, thoracic impedance has been shown to provide a noninvasive and simpler approach to continuously measure CO at rest and during exercise.Results show that measurements of CO are not different and highly reliable in response to repeated administrations of the Wingate test.Despite vastly different intensities and durations, maximal CO was similar between the Wingate test and graded exercise to VO2max.
منابع مشابه
Changes in Blood Gases and Hemodynamic Parameters in Patients Undergoing Lung Resection Surgery and Its Clinical Implications
Introduction: Lung resection surgery is a challenge to thoracic surgeons. Outcome of surgery depends on patients’ tolerance to reduced lung volume and hemodynamic alterations. The present study aimed to investigate the changes in blood gases and hemodynamic parameters in patients undergoing lung resection surgery and the associated clinical implications. Materials and methods: This study includ...
متن کاملComparison of the effect of gender on Hemodynamic factors and Normetanephrine after boxing exergame, with and without Blood flow restriction
Background: Despite the fact that researchers have recently turned their attention to the new style of video games with movement (exergames) and considering that these games have been recently accepted as a kind of sports activity with a wide range of people as audience of these games both male and female in various ages, not enough attentions have been paid to the comparison of different dimen...
متن کاملReproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease.
BACKGROUND Impedance cardiography (ICG) is a noninvasive method of determining hemodynamic parameters. It is clinically important to determine whether any change in ICG parameters occur due to changes in disease status or therapeutic interventions, or due to normal hemodynamic and technology variability. The objective of this study was to establish the intra- and inter-day reproducibility of IC...
متن کاملHemodynamic monitoring in heart failure and pulmonary hypertension: From analog tracings to the digital age
Hemodynamic monitoring has long formed the cornerstone of heart failure (HF) and pulmonary hypertension diagnosis and management. We review the long history of invasive hemodynamic monitors initially using pulmonary artery (PA) pressure catheters in the hospital setting, to evaluating the utility of a number of implantable devices that can allow for ambulatory determination of intracardiac pres...
متن کاملThe Interventional Effect of Dry Cupping Therapy and Creatine Supplementation on Lactic Acid, Lactate Dehydrogenase and Creatine Kinase in Plasma Following Wingate Anaerobic Test in Male Handball Players
Introduction: Optimum recovery can prevent the athlete's functional capacity from falling between training sessions or competitions. The aim of this study was to evaluate the effect of dry cupping therapy and creatine supplementation on lactic acid, lactate dehydrogenase and plasma creatine kinase following the Wingate anaerobic test in male handball players. Method: In this quasi-experimental...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 14 4 شماره
صفحات -
تاریخ انتشار 2015