Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke.
نویسندگان
چکیده
Computed tomography perfusion imaging in acute stroke requires further validation. We aimed to establish the optimal computed tomography perfusion parameters defining the infarct core and critically hypoperfused tissue. Sub-6-h computed tomography perfusion and 24-h magnetic resonance imaging were analysed from 314 consecutive patients with ischaemic stroke. Diffusion-weighted imaging lesion volume at 24 h was used to define the extent of critically hypoperfused tissue (in patients without reperfusion between acute and 24-h time points), and infarct core (in patients with major reperfusion at 24 h). Pixel-based analysis of co-registered computed tomography perfusion and diffusion-weighted imaging was then used to define the optimum computed tomography perfusion thresholds for critically hypoperfused at-risk tissue and infarct core. These optimized acute computed tomography perfusion threshold-based lesion volumes were then compared with 24-h diffusion-weighted imaging infarct volume, as well as 24-h and 90-day clinical outcomes for validation. Relative delay time >2 s was the most accurate computed tomography perfusion threshold in predicting the extent of critically hypoperfused tissue with both receiver operating curve analysis (area under curve 0.86), and the volumetric validation (mean difference between computed tomography perfusion and 24-h diffusion-weighted imaging lesions = 2 cm(2), 95% confidence interval 0.5-3.2 cm(2)). Cerebral blood flow <40% (of contralateral) within the relative delay time >2 s perfusion lesion was the most accurate computed tomography perfusion threshold at defining infarct core with both receiver operating characteristic analysis (area under curve = 0.85) and the volumetric validation. Using these thresholds, the extent of computed tomography perfusion mismatch tissue (the volume of 'at-risk' tissue between the critically hypoperfused and core thresholds) salvaged from infarction correlated with clinical improvement at 24 h (R(2) = 0.59, P = 0.04) and 90 days (R(2) = 0.42, P = 0.02). Patients with larger baseline computed tomography perfusion infarct core volume (>25 ml) also had poorer recovery at Day 90 (P = 0.039). Computed tomography perfusion can accurately identify critically hypoperfused tissue that progresses to infarction without early reperfusion, and the computed tomography perfusion cerebral blood flow infarct core closely predicts the final volume of infarcted tissue in patients who do reperfuse. The computed tomography perfusion infarct core and at-risk measures identified are also strong predictors of clinical outcome.
منابع مشابه
Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: the Dutch acute stroke trial (DUST) study protocol
BACKGROUND Prediction of clinical outcome in the acute stage of ischaemic stroke can be difficult when based on patient characteristics, clinical findings and on non-contrast CT. CT perfusion and CT angiography may provide additional prognostic information and guide treatment in the early stage. We present the study protocol of the Dutch acute Stroke Trial (DUST). The DUST aims to assess the pr...
متن کاملPerfusion computed tomography in patients with stroke thrombolysis
See Saver (doi:10.1093/awx020) for a scientific commentary on this article.Stroke shortens an individual's disability-free life. We aimed to assess the relative prognostic influence of pre- and post-treatment perfusion computed tomography imaging variables (e.g. ischaemic core and penumbral volumes) compared to standard clinical predictors (such as onset-to-treatment time) on long-term stroke d...
متن کاملPerfusion computed tomography to assist decision making for stroke thrombolysis
The use of perfusion imaging to guide selection of patients for stroke thrombolysis remains controversial because of lack of supportive phase three clinical trial evidence. We aimed to measure the outcomes for patients treated with intravenous recombinant tissue plasminogen activator (rtPA) at a comprehensive stroke care facility where perfusion computed tomography was routinely used for thromb...
متن کاملValidation of dynamic three-dimensional whole heart magnetic resonance myocardial perfusion imaging against single photon emission computed tomography for the detection of functionally significant coronary heart disease
We demonstrate the feasibility of 3D myocardial perfusion CMR at 3 Tesla against single photon emission computer tomography for the detection and estimate of ischaemic burden and show good agreement between the techniques. This novel technique shows promising use of this method in a small cohort of patients to estimate ischaemic burden for purpose of risk stratification of patients with known o...
متن کاملClinical review: Imaging in ischaemic stroke – implications for acute management
Imaging has become a cornerstone of stroke management, translating pathophysiological knowledge to everyday decision-making. Plain computed tomography is widely available and remains the standard for initial assessment: the technique rules out haemorrhage, visualizes the occluding thrombus and identifies early tissue hypodensity and swelling, which have different implications for thrombolysis. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Brain : a journal of neurology
دوره 134 Pt 11 شماره
صفحات -
تاریخ انتشار 2011