Dual-chamber pacemaker malfunction mimicking atrial capture by the ventricular electrode.
نویسندگان
چکیده
A 78-year-old man came for a scheduled check up one month after the implantation of a permanent dualchamber pacemaker for symptomatic transient atrioventricular conduction disturbances (intermittent Mobitz II atrioventricular block). The patient's ECG indicated a loss of atrial capture by the atrial electrode with 1:1 atrioventricular conduction. A subsequent X-ray examination showed that both electrodes were well placed and in their correct sites. A detailed check of the pacemaker using the programmer, together with an echocardiographic examination, revealed the true nature of the malfunction: there was a significant delay between the atrial capture and atrial depolarisation and systole, as well as a loss of ventricular capture because of an acute increase in the threshold. Normal pacemaker function and pacing ECG were restored through modification of the pacemaker's functional parameters.
منابع مشابه
Pseudofusion in a dual chamber pacemaker: Is this pacemaker working properly?
A 57-year-old womanwith a history of dizziness due to episodes of complete heart block and bradycardia was referred to the electrophysiology ward for pacemaker implantation. A dual chamber pacemaker (Medtronic, Relia, Medtronic, Minneapolis, USA) was implanted. Its analysis showed normal function (atrial lead capture threshold 0.5 V at 0.4 ms, ventricular lead capture threshold 0.75 V at 0.4 ms...
متن کاملLetter to the Editor: Marino et al. Inappropriate mode switching clarified by using a chest radiograph
To the Editor, I read with great interest the article by Marino et al. entitled “Inappropriate mode switching clarified by using a chest radiograph.” [1]. The authors have explained a case of dual-chamber pacemaker malfunction, caused by intermittent high-frequency noises. They claimed that this happened because of lead–lead interaction caused by excess slack of atrial and ventricular leads. In...
متن کاملHyperkalemia-induced failure of atrial capture during dual-chamber cardiac pacing.
This report describes hyperkalemia-induced failure of atrial capture associated with preservation of ventricular pacing in a patient with a dual-chamber (DDD) pacemaker. This differential effect on atrial and ventricular excitability during cardiac pacing correlates with the well known clinical and experimental observation that the atrial myocardium is more sensitive to hyperkalemia than is the...
متن کاملEarly complications of permanent pacemaker implantation: no difference between dual and single chamber systems.
OBJECTIVE To evaluate the incidence of intraoperative and early postoperative complications (up to two months after implant) of endocardial permanent pacemaker insertion in all patients under-going a first implant at a referral centre. METHODS Prospective evaluation of all endocardial pacemaker implantation procedures performed from April 1992 to January 1994 carried out by completion of stan...
متن کاملTermination of pacemaker-mediated tachycardia by a critically timed atrial extrasystole.
Pacemaker-mediated tachycardia (PMT) also called endless loop tachycardia is a macro-reentrant dual chamber pacemaker tachycardia conceptually similar to spontaneous reentrant supraventricular tachycardias (atrioventricular [AV] node reentrant tachycardia and orthodromic reciprocating tachycar-Figure 1. Termination of pacemaker-mediated tachycardia (PMT) by an atrial extrasystole. The tracing s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese
دوره 52 2 شماره
صفحات -
تاریخ انتشار 2011