Mid-Term Clinical Results of VerSys Hip System (Zimmer) Uncemented Total Hip Replacement Arthroplasty.

نویسندگان

  • Hidemi Kawaji
  • Takuya Uematsu
  • Naoya Hoshikawa
  • Hiroshi Watanabe
  • Shinro Takai
چکیده

Recent reports suggest that uncemented total hip replacement arthroplasty (THR) results in favorable short- to mid-term clinical results. In the present study, we assessed the mid-term clinical results of VerSys Hip System uncemented THR at our hospital. MATERIALS AND METHODS We studied patients who received THR using VerSys Hip System and who could be followed-up more than 3 years. Clinical records were used to retrospectively identify patient characteristics, which included age, gender, disease requiring THR, preoperative and postoperative pain score of the Japan Orthopaedic Association scoring system, range of motion in flexion and abduction, operating time, intraoperative complication, and additional operation or revision surgery. Additionally, we investigated the loosening and alignment of implants from X-ray films. RESULTS Ninety-one patients and 108 hip joints were investigated. Subjects were 11 males and 97 females (mean age, 64.6 years). Mean follow-up period was 6.9 years. Reasons for requiring THR were as follows: secondary osteoarthritis, 87 joints; idiopathic osteonecrosis of the femoral head, 16 joints; rapidly destructive coxarthrosis, 4 joints; and idiopathic ossification of the labrum, 1 joint. Mean operating time was 166 minutes. A total of 11 intraoperative fractures occurred, and wiring was performed in 3 of those cases. Adverse events pertaining to the surgery were limited; however, another adverse event was that 1 case resulted in intraoperative perforation of femoral cortex, for which a revision surgery was performed. There was no dislocation. Pain score using the Japan Orthopaedic Association scoring system and range of motion tests showed statistically significant improvement following THR. At the final follow-up, although no loosening of femoral implants was observed, the loosening of acetabular component was seen in 1 case. Varus insertion of femoral implant was recognized in 40 joints. Moreover, the average inclination angle of acetabular implants was 52.2 degrees. CONCLUSION These data suggest that patients receiving VerSys Hip System uncemented THR demonstrate favorable results pertaining pain score and range of motion. However, high rate of intraoperative fracture and malalignment of implants, which may be at a risk of dislocation and/or polyethylene wear in future, suggests that this implant technique requires improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cemented or uncemented femoral component in primary total hip replacement? A review from a clinical and radiological perspective.

Controversy exists regarding the optimal method of fixation for primary total hip replacement, particularly the femoral component. We performed a systematic literature review to explore whether cemented total hip replacement can achieve better clinical and radiological outcomes. A total of 29 publications were selected using computer-aided and manual searches. A qualitative comparison of result...

متن کامل

The relative cost of cemented and uncemented total hip arthroplasties.

The use of uncemented femoral stems in primary total hip arthroplasty (THA) has been slow to develop in the UK because of the lack of encouraging published long-term follow-up data, the continued success of the cemented primary THA, and the perceived excessive relative cost of the uncemented THA. In this article, we argue that the total costs of 3 "proven" uncemented stems are comparable with c...

متن کامل

Bilateral, uncemented total hip arthroplasty in osteopetrosis.

Bilateral, uncemented hip replacements were performed on a 45-year-old woman with autosomal dominant osteopetrosis. The hips showed degenerative changes and protrusio acetabuli. Difficulties were encountered especially during preparation of the femoral canal. At ten-year follow-up she has an excellent clinical and radiological result with no sign of osteolysis. Uncemented hip replacement, while...

متن کامل

Uncemented total hip arthroplasty in chronic hemodialysis patients

BACKGROUND AND PURPOSE Whether or not uncemented total hip arthroplasty (THA) can achieve durable fixation of implants to bone in patients on chronic hemodialysis is unknown. We analyzed the 2-13-year clinical outcomes of cementless THA in patients with end-stage renal diseases who were maintained on long-term hemodialysis. PATIENTS AND METHODS We reviewed the outcome of 23 consecutive unceme...

متن کامل

Influence of Femoral Implant Alignment in Uncemented Total Hip Replacement Arthroplasty: Varus Insertion and Stress Shielding.

BACKGROUND The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. MATERIALS AND METHODS The study participants included 89 patients who underwent unc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 2016