Finite element analysis of mono- and bicortical mini-implant stability.

نویسندگان

  • Christof Holberg
  • Philipp Winterhalder
  • Ingrid Rudzki-Janson
  • Andrea Wichelhaus
چکیده

OBJECTIVES Loosening and loss rates of monocortical mini-implants are relatively high, therefore the following null hypothesis was tested: 'The local bone stress in mono and bicortically-anchored mini-implants is identical'. MATERIAL AND METHODS Anisotropic Finite Element Method (FEM) models of the mandibular bone, including teeth, periodontal ligaments, orthodontic braces, and mini-implants of varying length, were created. The morphology was based on the Computed Tomography data of an anatomical preparation. All mini-implants with varying insertion depths (monocortical short, monocortical long, bicortical) were typically loaded, and the induced effective stress was calculated in the cervical area of the cortical bone. The obtained values were subsequently analysed descriptively and exploratively using the SPSS 19.0 software. RESULTS The null hypothesis was rejected, since the stress values of each anchorage type differed significantly (Kruskal-Wallis Test, P < 0.001). Therefore, the lowest effective stress values were induced in bicortical anchorage (mean = 0.65MPa, SD = 0.06MPa) and the highest were induced in monocortical (short) anchorage of the mini-implants (mean = 1.79MPa, SD = 0.29MPa). The Spearman rank correlation was 0.821 (P < 0.001). CONCLUSIONS The deeper the mini-implant was anchored, the lower were the effective stress values in the cervical region of the cortical bone. Bicortical implant anchorage is biomechanically more favourable than monocortical anchorage; therefore, bicortical anchorage should be especially considered in challenging clinical situations requiring heavy anchorage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-Dimensional Finite Element Analysis of Anterior Single Implant-Supported Prostheses with Different Bone Anchorages

The aim of this study was to evaluate the stress distribution of monocortical and bicortical implant placement of external hexagon connection in the anterior region of the maxilla by 3D finite element analysis (FEA). 3D models were simulated to represent a bone block of anterior region of the maxilla containing an implant (4.0 × 10.0 mm) and an implant-supported cemented metalloceramic crown of...

متن کامل

Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis.

PURPOSE Clarification of the protocol for using short implants is required to enable widespread use of short implants as an available treatment option. The purpose of this study was to investigate the influences of implant length and diameter, bicortical anchorage, and sinus augmentation on peri-implant cortical bone stress by three-dimensional finite element analysis. MATERIALS AND METHODS F...

متن کامل

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2014