Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.

نویسندگان

  • Doris Malehsa
  • Anna L Meyer
  • Christoph Bara
  • Martin Strüber
چکیده

Instead of pulsatile ventricular assist devices an increasing number of nonpulsatile ventricular assist devices are introduced to clinical practice. The different flow characteristics of this new technique lead to alteration in shear stress on blood components, which may affect the coagulation system. Repeated von Willebrand factor analyses were performed in a patient who first was implanted with a pulsatile ventricular assist device (Thoratec HeartMate XVE), which had to be replaced after 405 days with an axial flow device (HeartMate II). During support with the pulsatile ventricular assist device there was no sign of any coagulation disorder. However, on the axial flow device acquired von Willebrand syndrome Type 2 developed. Inhibition of platelet function was also observed, which may be in part due to the von Willebrand syndrome. The HeartMate II axial flow device may induce von Willebrand syndrome, which was not observed in HeartMate XVE pulsatile ventricular assist device. Patients put on continuous flow devices should be screened for acquired von Willebrand syndrome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.

OBJECTIVES The aim of this study was to determine whether differences in continuous flow left ventricular assist devices (LVADs) may lead to differences in the von Willebrand profile and the occurrence of bleeding and thromboembolic events. BACKGROUND The HeartMate II (Thoratec Corp., Pleasanton, California) and HeartWare Ventricular Assist Device (HVAD) (HeartWare, Inc., Framingham, Massachu...

متن کامل

Editorial comment: Adverse events in long-term ventricular assist device therapy.

the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...

متن کامل

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

Platelet Secretion Defects and Acquired von Willebrand Syndrome in Patients With Ventricular Assist Devices

BACKGROUND The number of implanted ventricular assist devices (VADs) has increased significantly recently. Bleeding, the most frequent complication, cannot be solely attributed to anticoagulation therapy. Acquired von Willebrand syndrome (AVWS) caused by increased shear stress is frequent in VAD patients and can increase the bleeding risk. The HeartMate III (HM III) is a novel left VAD featurin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2009