Dosimetric comparison of left-sided whole breast irradiation with 3D-CRT, IP-IMRT and hybrid IMRT.
نویسندگان
چکیده
The aim of this study was to compare the dosimetric characteristics of left-sided whole breast irradiation among 3-dimensional conformal radiotherapy (3D-CRT), 4-field inverse-planned intensity-modulated radiotherapy (IP-IMRT) and hybrid IMRT technique (combining 3D-CRT beams and IP-IMRT beams) with respect to target coverage and irradiation of organs at risk. The 3 different planning techniques were analyzed for 8 patients with left-sided breast conserving surgery. Plans were compared on the basis of planning target volume (PTV) dose conformity, homogeneity and the volumes of normal tissues treated based on dose-volume histograms (DVHs). DVHs were calculated for the PTV, heart, and the bilateral lungs, contralateral breast, and soft tissue surrounding the breast PTV (VOB) volume. IP-IMRT and hybrid IMRT techniques comparably improved the PTV dose homogeneity and conformity (CI) significantly, compared to the conventional 3D-CRT technique (P<0.017); the IP-IMRT technique only could additionally benefit patients by decreasing the high-dose (40 Gy) volume for heart and ipsilateral lung compared with the hybrid IMRT technique (P<0.017); the hybrid IMRT plans achieved a further improvement by compromising the increase of low-dose volume (total lung V13, contralateral lung V5, heart V10 and soft tissue surrounding the breast V5) compared with IP-IMRT plans (P<0.017). Hybrid IMRT plans achieved equivalent PTV dose uniformity to IP-IMRT plans and compromised the low-dose volume and requirement of clinic resource between IP-IMRT and 3D-CRT plans, promoting it as a standard practice of left-sided breast irradiation for patients in good-ordered cardiopulmonary health.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملDosimetric evaluation of the skin-sparing effects of 3-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left breast cancer
The purpose of this study was to evaluate the skin-sparing effects of 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in patients with early left-sided breast cancer. Twenty left breast cancer patients treated with whole breast radiotherapy following breast-conserving surgery were enrolled in this study, and the 3D-CRT and IMRT plans were generated for ...
متن کاملDosimetric evaluation of incidental irradiation to the axilla during whole breast radiotherapy for patients with left-sided early breast cancer in the IMRT era
The purpose of this study was to compare the dosimetric parameters for incidental irradiation to the axilla during whole breast radiotherapy (WBRT) with 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). Twenty left breast cancer patients treated with WBRT after breast-conserving surgery (BCS) were enrolled in this study. Remnant breast tissue, 3 levels o...
متن کاملComparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)
Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients. Materials and Methods: Co...
متن کاملThe feasibility of a heart block with an electron compensation as an alternative whole breast radiotherapy technique in patients with underlying cardiac or pulmonary disease
PURPOSE We aimed to evaluate the feasibility of the heart block with electron compensation (HBE) technique, based on three-dimensional conformal radiotherapy (3D-CRT) in left-sided breast cancer patients with underlying cardiac or pulmonary disease. METHODS Twenty patients with left-sided breast cancer who were treated with whole breast radiotherapy (WBRT) were included in this study. Intensi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Oncology reports
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2014