Pseudotumor associated with metal-on-polyethylene total hip arthroplasty.

نویسندگان

  • William F Scully
  • Steven M Teeny
چکیده

This case report details the presentation, imaging results, and operative findings of a pseudotumor associated with a press-fit metal-on-polyethylene total hip arthroplasty (THA). An 80-year-old man presented approximately 7 years after undergoing THA with worsening right groin and lateral hip pain with an associated proximal thigh mass. Physical examination demonstrated a tender, large anterolateral thigh mass that was also evident on metal artifact reduction sequence magnetic resonance imaging.An exploratory operative procedure revealed extensive tissue necrosis involving nearly the entire hip capsule, short external rotators, and tendinous portion of the gluteus medius muscle. In addition, marked surface corrosion was discovered about the taper at the head-neck junction of the prosthetic femoral component and the trunnion within the femoral head. The press-fit THA components were solidly fixed. The metallic head was replaced with a ceramic component, and the polyethylene liner was exchanged. The patient had complete resolution of his preoperative symptoms but had persistent problems with dislocations.Although reports of pseudotumor and local soft tissue reactions associated with metal-on-metal THAs have become increasingly ubiquitous in the literature, similar reports involving metal-on-polyethylene THA implants are less common.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Growth of an intrapelvic pseudotumor associated with a metal-on-metal total hip arthroplasty after revision arthroplasty causing a femoral nerve neuropathy

The development of pseudotumors is not uncommon with metal-on-metal total hip arthroplasty. Pseudotumors that dissect into the retroperitoneal space can cause symptoms of nerve compression. We describe a case of a 53-year-old male with a metal-on-metal total hip arthroplasty who developed mild symptoms of a femoral nerve neuropathy 6 years postoperatively. Revision arthroplasty to a ceramic-on-...

متن کامل

Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty

A 71-year-old female with a history of right total hip arthroplasty presented with an enlarging pseudotumor. Pseudotumor is a known complication following metal-on-metal and metal-on-conventional polyethylene and metal-on-highly cross-linked polyethylene implants. Revision total hip arthroplasty following resection of pseudotumor has resulted in an increase in incidence of postoperative complic...

متن کامل

Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty i...

متن کامل

Pseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report

INTRODUCTION Pseudotumor is not an uncommon complication after total hip arthroplasty (THA). This can occur in relationship to different bearing surfaces of head and liner ranging from soft to hard articulation. There is wide spectrum of presentation from asymptomatic to implant failure. CASE REPORT We report a case of pseudotumor formation with acetabular cup aseptic loosening after revision...

متن کامل

Inflammatory pseudotumor around metal-on-polyethylene total hip arthroplasty in patients with ankylosing spondylitis: description of two cases and review of literature

Inflammatory pseudotumor has been commonly reported in patients undertaking total hip replacement (THR) for different reasons. The precise etiology of this biological reaction and whether the primary disease has an influence on pseudotumor formation remain unclear. There seems to be a consensus that metal ions and debris do play an important role during this process. Recently, however, compared...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2013