Removal of distortion from indicator dilution curves with analog computer.

نویسندگان

  • J K COOPER
  • J R SCHWEIKERT
  • T G ARNOLD
  • W W LACY
چکیده

• In the usual procedure for determination of indicator dilution curves, the sensing or measuring device is placed at some distance from the sampling site. The fluid is transported by a sampling system, usually a cathe-ter, from the withdrawal site to the sensing point. This sampling system always introduces some distortion in the time-concentration curve, so that the recorded curve is not the same shape as the in situ concentration-time relation at the withdrawal site. These sampling errors have been described by several workers. 1-2 ' 3i * In an effort to eliminate the sampling system error, other systems that place the sensing device directly at the point of observation have been described. Hydrogen electrodes, radioactive counting devices, conductivity electrodes, and thermocouples have been used, but each has introduced new problems. The continued use of indicator dilution procedures using photodensitometry has the advantages of offering rapid response and high sensing efficiency of signal. There is widespread experience with the technique, and the indicators have low toxicity. It seems advantageous, then, to devise a system that would produce curves that did not contain the sampling system distortion. If the concentration-time relation at the point being investigated, c(t), is considered the "actual input curve (to the catheter)," then its distorted version, seen by the densi-tometer after passage through the catheter can be considered the "distorted downstream curve," Cti(t), (where c and c d represent concentration and t, time). If the distorting property* of the catheter can be characterized , then by using the analog computer, any distorted curve, c (i(t), can be transformed into the actual input curve, e(t). A convenient method of analyzing the distorting function of an indicator sampling system is to introduce a sudden square step of concentration change. If the downstream distorted curve is compared to the square step input, the distorting function can be evaluated. This characteristic will be applicable to any other concentration input, providing the distorting function of the catheter does not change during the procedure. If all the concentration curves are available in an electrical form (where concentration is analagous to voltage), then the distorting function can be determined directly with an analog computer. Once this is done, correction of distorted curves is feasible. It is necessary, then, to set up a sampling system and put into it a square step change, knowing both the input curve and the downstream distorted curve. From this, …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Correction of Catheter Distortion on Calculated Liver Sinusoidal Volumes.

GORESKY, CARL A., AND MELVIN SILVERMAN. Eject ofcmection of catheter distortion on calculated liver sinusoidal volumes. Am. J. Physiol. 207(a) : 883-892. I 964. -The use of a collecting system to obtain samples in the multiple indicator-dilution technique produces delay in and distortion of the dilution curves. A method for removing these is described and the method is applied, using an analog ...

متن کامل

A figure of merit for catheter sampling systems.

The distortion of indicator dilution curves by catheter sampling systems is predictable from theoretic considerations based on laminar flow. Over a wide range of catheter and flow parameters, deductions can be made regarding distortion, by the arterial system or by sampling catheters, of indicator dilution curves coming from an idealized pump. A figure of merit for the sampling system is given ...

متن کامل

The Use of Ascorbate Dilution Curves

AT THE PRESENT time, indicator-dilution curves are one of the most important technics employed in the investigation of the circulation. The earliest of these studies were carried out by the rapid serial collections of blood samples and their subsequent photometric analysis.' This ingenious but cumbersome method was replaced by the continuous withdrawal of blood in front of a photoelectric cell,...

متن کامل

THD Analysis in Closed-Loop Analog PWM Class-D Amplifiers

In this paper, we investigate the parameters affecting Total Harmonic Distortion (THD) and Power Supply Rejection Ratio (PSRR) in PWM Class D Amplifiers (CDAs) on the basis of linear models with feedback. From our mathematical analysis, we show that the THD of a PWM Class D amplifier with feedback can be improved by increasing the gain of the integrator through adding another amplifier at the o...

متن کامل

Effect of coronary blood flow on radioiosotope dilution curves measured by precordial scintillation detection.

IN a comparison of radioactive bolus dilution curves obtained simultaneously by external monitoring' over the preeordium and by sampling from a peripheral artery, it was noted that arterial curves had a more rapid disappearance rate than precordial curves. This observation, made originally in human subjects, led to an investigation in animals designed to determine the reason for the distortion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 12  شماره 

صفحات  -

تاریخ انتشار 1963