Preparation of tetraheptylammonium iodide-iodine graphite-multiwall carbon nanotube paste electrode: electrocatalytic determination of ascorbic acid in pharmaceuticals and foods.

نویسندگان

  • Meissam Noroozifar
  • Mozhgan Khorasani-Motlagh
  • Hamed Tavakkoli
چکیده

The present work describes the construction of a new modified graphite-multiwall carbon nanotube paste electrode by casting the appropriate mixture of tetraheptylammonium iodide-iodine as a new modifier. The modified paste electrode was used for the determination of ascorbic acid (AA) in a phosphate buffer solution (pH 2.0). When compared to activated carbon, a graphite and multiwall carbon nanotube paste electrode containing a new modifier, the proposed modified paste electrode not only shifted the oxidation potential of AA towards a less-positive potential but also enhanced its oxidation peak current. Further, the oxidation of AA was highly stable at the modified paste electrode. The optimum analytical conditions were sought. The current response of AA increases linearly while increasing its concentration from 5.6 × 10(-5) to 1.2 × 10(-2) M with a correlation coefficient of 0.9991; the detection limit (3σ) was found to be of 3.6 × 10(-5) M. The present modified paste electrode was also successfully used for the determination of AA in the presence of common interference compounds. The present modified electrode was successfully demonstrated towards the determination of AA in pharmaceutical and food samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of ascorbic acid by a modified multiwall carbon nanotube paste electrode using cetrimonium iodide/iodine

A new modified graphite-multiwall carbon nanotube paste electrode for the determination of ascorbic acid (AA) based on cetrimonium iodide-iodine is described. The electrochemical response characteristics of the modified electrode toward AA were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in phosphate buffer solution (pH 2.0). When compared to activated carbo...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Voltammetric Determination of Ascorbic Acid and Uric Acid Using a Modified Multiwalled Carbon Nanotube Paste Electrode

This paper describes the development, electrochemical characterization and utilization of novel modified molybdenum (VI) complex-carbon nanotube paste electrode for the electrocatalytic determination of ascorbic acid (AA). The electrochemical profile of the proposed modified electrode was analyzed by cyclic voltammetry (CV) that showed a shift of the oxidation peak potential of AA about 235 mV ...

متن کامل

Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode

A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 9  شماره 

صفحات  -

تاریخ انتشار 2011