Millimeter-resolution acousto-optic quantitative imaging in a tissue model system.
نویسندگان
چکیده
We have investigated the application of ultrasound modulated coherent light for quantitative determination of the ratio of dye concentrations and total concentration of absorbers in a blood vessel-mimicking sample. A 3-mm-diam tube containing the mixture of dyes inside an Intralipid-based gel with optical properties similar to tissue was interrogated by two different laser wavelengths in combination with intense microsecond ultrasound bursts. The use of calibration curves allowed us to extract quantitative information on the ratio of dye concentrations with the accuracy of better than 15%, as well as on the total concentration. Furthermore, we demonstrated the feasibility to obtain a quantitative 3-D map of the absorbing structure with a spatial resolution of better than 3 mm. These findings give an outlook to apply this technique for noninvasive 3-D mapping of oxygen saturation and total concentration of hemoglobin in tissue.
منابع مشابه
Nonlinear effects in acousto-optic imaging.
Acousto-optic (AO) imaging is a promising technique that is able to reveal optical properties in the millimeter range inside scattering media by tagging the photon paths with an ultrasonic beam. To increase both the contrast and the resolution of the AO images, we have explored the possibility of using the nonlinear response of the speckle modulation. Variation of the second-harmonic signal as ...
متن کاملAcousto-optical coherence tomography with a digital holographic detection scheme.
Acousto-optical coherence tomography (AOCT) consists in using random phase jumps on ultrasound and light to achieve a millimeter resolution when imaging thick scattering media. We combined this technique with heterodyne off-axis digital holography. Two-dimensional images of absorbing objects embedded in scattering phantoms are obtained with a good signal-to-noise ratio. We study the impact of t...
متن کاملExperimental study of z resolution in acousto-optical coherence tomography using random phase jumps on ultrasound and light.
Acousto-optical coherence tomography (AOCT) is a variant of acousto-optic imaging (also called ultrasound modulated optical tomography) that makes possible to get resolution along the ultrasound propagation axis z. We present here AOCT experimental results, and we study how the z resolution depends on time step between phase jumps T(φ), or on the correlation length Δz. By working at low resolut...
متن کاملFast Acousto-optic Tissue Sensing with Tandem Nanosecond Pulses Experiments and Theory
Acousto-optics (AO) is an emerging hybrid technique for measuring optical contrast in turbid media with the use of coherent light and ultrasound (US). The turbid object of interest is illuminated with a coherent light source and as a consequence a speckle pattern is formed. With the use of US a small volume of interest is selected, which is commonly referred to as the ‘tagging’ volume. This vol...
متن کاملSub-millimeter Voxel Diffusion Tensor Imaging of the Optic Chiasm
Introduction: Diffusion tensor MRI (DTI) has become a powerful tool for the investigation into tissue architecture and integrity. However, there are numerous anatomical details in the brain that are undetectable at typical DTI image resolution, being 8mm3 voxels, due to partial volume effects and the sequence used in the majority of DTI studies, single -shot EPI, is sensitive to magnetic field ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 14 3 شماره
صفحات -
تاریخ انتشار 2009