Dimensions of the human sclera: Thickness measurement and regional changes with axial length.

نویسندگان

  • Richard E Norman
  • John G Flanagan
  • Sophie M K Rausch
  • Ian A Sigal
  • Inka Tertinegg
  • Armin Eilaghi
  • Sharon Portnoy
  • John G Sled
  • C Ross Ethier
چکیده

Scleral thickness, especially near the region of the optic nerve head (ONH), is a potential factor of interest in the development of glaucomatous optic neuropathy. Our goal was to characterize the scleral thickness distribution and other geometric features of human eyes. Eleven enucleated human globes (7 normal and 4 ostensibly glaucomatous) were imaged using high-field microMRI, providing 80 microm isotropic resolution over the whole eye. The MRI scans were segmented to produce 3-D corneoscleral shells. Each shell was divided into 15 slices along the anterior-posterior axis of the eye, and each slice was further subdivided into the anatomical quadrants. Average thickness was measured in each region, producing 60 thickness measurements per eye. Hierarchical clustering was used to identify trends in the thickness distribution, and scleral geometric features were correlated with globe axial length. Thickness over the whole sclera was 670 +/- 80 microm (mean +/- SD; range: 564 microm-832 microm) over the 11 eyes. Maximum thickness occurred at the posterior pole of the eye, with mean thickness of 996 +/- 181 microm. Thickness decreased to a minimum at the equator, where a mean thickness of 491 +/- 91 microm was measured. Eyes with a reported history of glaucoma were found to have longer axial length, smaller ONH canal dimensions and thinner posterior sclera. Several geometrical parameters of the eye, including posterior scleral thickness, axial length, and ONH canal diameter, appear linked. Significant intra-individual and inter-individual variation in scleral thickness was evident. This may be indicative of inter-individual differences in ocular biomechanics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressure-induced changes in axial eye length of chick and tree shrew: significance of myofibroblasts in the sclera.

PURPOSE To investigate the change in axial eye dimensions resulting from stretching the sclera by acute elevation of intraocular pressure (IOP). METHODS IOP was increased to 100 mm Hg for 1 hour through an intravitreal cannula, while ocular component dimensions were monitored every 10 minutes with A-scan ultrasound in anesthetized animals (10 chicks and 10 tree shrews). In addition, immunocyt...

متن کامل

To Estimate the Axial Elastic Modulus of Eye and Posterior Wall Thickness in Healthy Human Eye by Ultrasound Images and their Relation with Age and Gender

Introduction: Based on the invasive studies it has been shown that factors such as age, the progress of eye disorders, lens fibers compression and the biochemical changes of ocular matrix alter the physical characteristics and elastic properties of eye. In this study, a noninvasive method of estimating human eye elasticityis proposed and its relation with age and gender is evaluated using ultra...

متن کامل

Scleral Cross Section Area and Volume and Axial Length

PURPOSE To examine whether the scleral cross sectional area and estimated scleral volume are associated with a longer axial length in human eyes. METHODS Histologic anterior-posterior sections running through the pupil and the optic nerve head were examined. Using a light microscope, we measured the thickness of the sclera at the limbus, ora serrata, equator, midpoint between equator and post...

متن کامل

Peripapillary Arterial Circle of Zinn-Haller: Location and Spatial Relationships with Myopia

PURPOSE To measure histomorphometrically the location of the peripapillary arterial circle of Zinn-Haller (ZHAC) and assess its associations with axial length. METHODS Using a light microscope, we measured the distance from the ZHAC to the peripapillary ring (optic disc border), the merging point of the dura mater with the posterior sclera ("dura-sclera point"), and the inner scleral surface....

متن کامل

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental eye research

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2010