High power electron accelerators for radiation processing and its safety aspects
نویسنده
چکیده
Electron accelerators from 500 keV to 10 MeV energy are employed for surface irradiation, food preservation, medical sterilization, cargo scanning and other industrial products. At EBC, a 10 MeV Linac has been indigenously developed and is operational for radiation processing. This is an on-axis coupled cavity standing wave type of RF linac operating with 50-70 keV electron gun having LaB6 cathode and klystron-based RF source at 2856 MHz. The linac is currently operating at 10 MeV, 130 mA (peak), 10 μs pulses at a prf of 415 Hz and is employed for various experiments. A similar 9 MeV linac is operational for cargo-scanning. A compact 6 MeV linac is under development. A 500 keV, 3 kW dc accelerator based on Cockroft Walton multiplier has been operational for industrial surface processing. A 3 MeV dc accelerator based on parallel coupled multiplier column is operational at 1 MeV, 4.6 kW level. A 700 keV, 5 kW dc machine for cross-linking and graft polymerization is under development. A 100 MeV, 100 kW electron Linac for producing intense neutron source has been proposed for development. Technological developments, operating experiences, utilization for industrial applications and safety aspects of all facilities are described.
منابع مشابه
Radiation protection at high energy electron accelerators.
An overview is presented of radiation protection at high energy electron accelerator facilities. By 'high energy' is meant the energy domain beyond a few tens of MeV, where electromagnetic showers are the determining and dominant factor for beam interactions with matter. The basic components of electron accelerators are described and their potential impact on radiation safety. The paper then co...
متن کاملOperational radiation protection in synchrotron light and free electron laser facilities.
The third-generation synchrotron radiation (SR) facilities are storage ring-based facilities with many insertion devices and photon beamlines, and have low injection beam power, but extremely high stored beam power. The fourth-generation X-ray free electron laser (FEL) facilities are based on an electron Linac with a long undulator and have high injection beam power. Due to its electron and pho...
متن کاملHigh-Gain Free Electron Lasers Using Induction Linear Accelerators
High-power free electron lasers (FEL’s) can be realized using induction linear accelerators as the source of the electron beam. These accelerators are currently capable of producing intense cwrents (102-104 A) at moderately high energy (1-50 MeV). Experiments using a 500 A, 3.3 MeV beam have produced 80 MW of radiation at 34.6 GHz and are in good agreement with theoretical analysis. Future expe...
متن کامل10 Radiation Safety Yoshihiro Asano
Radiation safety is one of the most important issues for free electron laser [FEL] facilities and the users. Many FEL facilities are under operation worldwide, and their number is growing. The wave length of FEL ranges from a few millimeters to about 0.5 nm, and the electron energy is from a few MeV to about 20 GeV. Furthermore, various kinds of electron accelerator types are constructed for FE...
متن کاملAutomated High-power Conditioning of Medical Accelerators
Medical accelerators require arc-free operation. Due to high-field emission, arcing and outgassing can occur in high-power accelerators. Therefore, the accelerators inner surfaces have to be conditioned before its use at high gradient levels in Radiation Therapy machines. At Siemens, we have developed a technique to automatically condition accelerator structures by continually inspecting the a...
متن کامل