Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis.
نویسندگان
چکیده
We developed a powered ankle-foot orthosis that uses artificial pneumatic muscles to produce active plantar flexor torque. The purpose of this study was to quantify the mechanical performance of the orthosis during human walking. Three subjects walked at a range of speeds wearing ankle-foot orthoses with either one or two artificial muscles working in parallel. The orthosis produced similar total peak plantar flexor torque and network across speeds independent of the number of muscles used. The orthosis generated approximately 57% of the peak ankle plantar flexor torque during stance and performed approximately 70% of the positive plantar flexor work done during normal walking. Artificial muscle bandwidth and force-length properties were the two primary factors limiting torque production. The lack of peak force and work differences between single and double muscle conditions can be explained by force-length properties. Subjects altered their ankle kinematics between conditions resulting in changes in artificial muscle length. In the double muscle condition greater plantar flexion yielded shorter artificial muscles lengths and decreased muscle forces. This finding emphasizes the importance of human testing in the design and development of robotic exoskeleton devices for assisting human movement. The results of this study outline the mechanical performance limitations of an ankle-foot orthosis powered by artificial pneumatic muscles. This orthosis could be valuable for gait rehabilitation and for studies investigating neuromechanical control of human walking.
منابع مشابه
An ankle-foot orthosis powered by artificial pneumatic muscles.
We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force ...
متن کاملAn improved powered ankle-foot orthosis using proportional myoelectric control.
We constructed a powered ankle-foot orthosis for human walking with a novel myoelectric controller. The orthosis included a carbon fiber and polypropylene shell, a metal hinge joint, and two artificial pneumatic muscles. Soleus electromyography (EMG) activated the artificial plantar flexor and inhibited the artificial dorsiflexor. Tibialis anterior EMG activated the artificial dorsiflexor. We c...
متن کاملTargeting specific muscles for rehabilitation with an EMG-controlled ankle-foot orthosis
In able-bodied individuals, the ankle provides more positive work during the stance phase of gait, especially at push-off, than both the knee and the hip [1]. Neurological injuries, such as stroke, weaken neural connections to distal muscles, specifically to those muscles which act about the ankle joint. The result is a reduction in the amount of positive work the ankle can provide [2]. Therefo...
متن کاملThe Effects of Modified Ankle Foot Orthosis on balance in Healthy Older People
Introduction: Balance impairment and related injuries are common in elderly and patients with neurologic disorders. Ankle foot orthosies can influence on balance via improvement of movement disorders. Therefore the aim of this study was to investigate the effects of modified ankle-foot orthosis on balance performance in healthy elderly. Materials & Methods: The research was conducted on ten ...
متن کاملComparing the Effects of Flexible and Rigid Ankle-Foot Orthoses on Balance/Walking Performance in Individuals With Multiple Sclerosis
Background: Ankle-Foot orthoses are used to minimize the impact of weakness in ankle dorsiflexion muscles. The study on different orthotic types defines the optimal design, which effectively improves the users’ mobility. This study investigated the potential benefits and risks of a Dictus-band (flexible orthotic), compared with a thermoplastic (fixed) ankle-foot orthosis on the mobility of indi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2006