Structural and mechanical evaluations of a topology optimized titanium interbody fusion cage fabricated by selective laser melting process.

نویسندگان

  • Chia-Ying Lin
  • Tobias Wirtz
  • Frank LaMarca
  • Scott J Hollister
چکیده

A topology optimized lumbar interbody fusion cage was made of Ti-Al6-V4 alloy by the rapid prototyping process of selective laser melting (SLM) to reproduce designed microstructure features. Radiographic characterizations and the mechanical properties were investigated to determine how the structural characteristics of the fabricated cage were reproduced from design characteristics using micro-computed tomography scanning. The mechanical modulus of the designed cage was also measured to compare with tantalum, a widely used porous metal. The designed microstructures can be clearly seen in the micrographs of the micro-CT and scanning electron microscopy examinations, showing the SLM process can reproduce intricate microscopic features from the original designs. No imaging artifacts from micro-CT were found. The average compressive modulus of the tested caged was 2.97+/-0.90 GPa, which is comparable with the reported porous tantalum modulus of 3 GPa and falls between that of cortical bone (15 GPa) and trabecular bone (0.1-0.5 GPa). The new porous Ti-6Al-4V optimal-structure cage fabricated by SLM process gave consistent mechanical properties without artifactual distortion in the imaging modalities and thus it can be a promising alternative as a porous implant for spine fusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting

Developments in selective laser melting (SLM) have enabled the fabrication of periodic cellular lattice structures characterized by suitable properties matching the bone tissue well and by fluid permeability from interconnected structures. These multifunctional performances are significantly affected by cell topology and constitutive properties of applied materials. In this respect, a diamond u...

متن کامل

Trapezoidal titanium cage in anterior cervical interbody fusion: a clinical experience.

BACKGROUND Use of autogenous bone grafting taken from anterior iliac crest for anterior cervical interbody fusion has been the "gold-standard" for decades. Substitutes for autogenous bone graft continue to be sought to avoid potential donor site morbidity. A titanium-alloy square-shaped hollow cage was applied to facilitate the process of fusion as a bone graft substitute, then assessed in this...

متن کامل

Comparison of high‐intensity sound and mechanical vibration for cleaning porous titanium cylinders fabricated using selective laser melting

Orthopedic components, such as the acetabular cup in total hip joint replacement, can be fabricated using porous metals, such as titanium, and a number of processes, such as selective laser melting. The issue of how to effectively remove loose powder from the pores (residual powder) of such components has not been addressed in the literature. In this work, we investigated the feasibility of two...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

In Situ Biodegradable Interbody Fusion Cage Design by the Integrated Global and Local Topolo- Gy Optimization - an Example on Designing Yucatan Minipig Lumbar Interbody Fusion Cage for Large Animal Study

IN SITU BIODEGRADABLE INTERBODY FUSION CAGE DESIGN BY THE INTEGRATED GLOBAL AND LOCAL TOPOLOGY OPTIMIZATION AN EXAMPLE ON DESIGNING YUCATAN MINIPIG LUMBAR INTERBODY FUSION CAGE FOR LARGE ANIMAL STUDY Hee Suk Kang1,3, Scott J. Hollister2,1,3, Frank LaMarca3,2, Chia-Ying Lin3,2 1Mechanical Engineering, University of Michigan, Ann Arbor, MI; 2Biomedical Engineering, University of Michigan, Ann Arb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part A

دوره 83 2  شماره 

صفحات  -

تاریخ انتشار 2007