Outcomes of Saphenous Vein Graft Intervention With and Without Embolic Protection Device: A Comprehensive Review and Meta-Analysis.

نویسندگان

  • Timir K Paul
  • Samit Bhatheja
  • Hemang B Panchal
  • Shimin Zheng
  • Subhash Banerjee
  • Sunil V Rao
  • Luis Guzman
  • Nirat Beohar
  • David Zhao
  • Roxana Mehran
  • Debabrata Mukherjee
چکیده

BACKGROUND Current guidelines give a class I recommendation to use of embolic protection devices (EPD) for saphenous vein graft (SVG) intervention; however, studies have shown conflicting results. The objective of this meta-analysis is to compare all-cause mortality, major adverse cardiovascular events, myocardial infarction (MI), or target vessel revascularization in SVG intervention with and without EPD. METHODS AND RESULTS Literature was searched through October 2016. Eight studies (n=52 893) comparing SVG intervention performed with EPD (n=11 506) and without EPD (n=41 387) were included. There was no significant difference in all-cause mortality (odds ratio [OR], 0.79; confidence interval [CI], 0.55-1.12; P=0.19), major adverse cardiovascular events (OR, 0.73, CI, 0.51-1.05; P=0.09), target vessel revascularization (OR, 1.0; CI, 0.95-1.05; P=0.94), periprocedural MI (OR, 1.12; CI, 0.65-1.90, P=0.69), and late MI (OR, 0.80; CI, 0.52-1.23; P=0.30) between the 2 groups. Sensitivity analysis excluding CathPCI Registry study showed no difference in periprocedural MI, late MI, and target vessel revascularization; however, it favored EPD use in all-cause mortality and major adverse cardiovascular events. Further sensitivity analysis including only observational studies revealed no difference in all-cause mortality, major adverse cardiovascular events, target vessel revascularization, and late MI. Additional analysis after excluding CathPCI Registry study revealed no difference in outcomes. CONCLUSIONS This study including 52 893 patients suggests no apparent benefit in routine use of EPD during SVG intervention in the contemporary real-world practice. Further randomized clinical trials are needed in current era to evaluate long-term outcomes in routine use of EPD, and meanwhile, current guideline recommendations on EPD use should be revisited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Embolic Protection Devices in Saphenous Vein Graft and Native Vessel Percutaneous Intervention: A Review

The clinical benefit of percutaneous intervention (PCI) depends on both angiographic success at the site of intervention as well as the restoration of adequate microvascular perfusion. Saphenous vein graft intervention is commonly associated with evidence of distal plaque embolization, which is correlated with worse clinical outcomes. Despite successful epicardial intervention in the acute MI p...

متن کامل

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

Randomized evaluation of the TriActiv balloon-protection flush and extraction system for the treatment of saphenous vein graft disease.

OBJECTIVES The Protection During Saphenous Vein Graft Intervention to Prevent Distal Embolization (PRIDE) study compared outcomes with the TriActiv System (Kensey Nash Corp., Exton, Pennsylvania), a balloon-protection flush and extraction device, with an embolic protection group during treatment of saphenous venous grafts (SVGs). BACKGROUND Treatment of SVGs with embolic protection reduces ad...

متن کامل

Adjuvant therapy of breast cancer in the elderly: does one size fit all?

6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...

متن کامل

Saphenous Vein Graft Dissection Using the GuardWire Distal Protection Balloon

The higher rate of periprocedural adverse events and lower rate of event-free survival of saphenous vein graft (SVG) intervention compared with native coronary artery intervention is primarily due to distal embolization. Distal embolic protection devices have been shown to reduce the incidence of no flow/slow flow and procedure related myocardial infarction during percutaneous intervention of d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 10 12  شماره 

صفحات  -

تاریخ انتشار 2017