High-precision measurements of seawater Pb isotope compositions by double spike thermal ionization mass spectrometry.
نویسندگان
چکیده
A new method for the determination of seawater Pb isotope compositions and concentrations was developed, which combines and optimizes previously published protocols for the separation and isotopic analysis of this element. For isotopic analysis, the procedure involves initial separation of Pb from 1 to 2L of seawater by co-precipitation with Mg hydroxide and further purification by a two stage anion exchange procedure. The Pb isotope measurements are subsequently carried out by thermal ionization mass spectrometry using a (207)Pb-(204)Pb double spike for correction of instrumental mass fractionation. These methods are associated with a total procedural Pb blank of 28±21 pg (1sd) and typical Pb recoveries of 40-60%. The Pb concentrations are determined by isotope dilution (ID) on 50 mL of seawater, using a simplified version of above methods. Analyses of multiple aliquots of six seawater samples yield a reproducibility of about ±1 to ±10% (1sd) for Pb concentrations of between 7 and 50 pmol/kg, where precision was primarily limited by the uncertainty of the blank correction (12±4 pg; 1sd). For the Pb isotope analyses, typical reproducibilities (±2sd) of 700-1500 ppm and 1000-2000 ppm were achieved for (207)Pb/(206)Pb, (208)Pb/(206)Pb and (206)Pb/(204)Pb, (207)Pb/(204)Pb, (208)Pb/(204)Pb, respectively. These results are superior to literature data that were obtained using plasma source mass spectrometry and they are at least a factor of five more precise for ratios involving the minor (204)Pb isotope. Both Pb concentration and isotope data, furthermore, show good agreement with published results for two seawater intercomparison samples of the GEOTRACES program. Finally, the new methods were applied to a seawater depth profile from the eastern South Atlantic. Both Pb contents and isotope compositions display a smooth evolution with depth, and no obvious outliers. Compared to previous Pb isotope data for seawater, the (206)Pb/(204)Pb ratios are well correlated with (207)Pb/(206)Pb, underlining the significant improvement achieved in the measurement of the minor (204)Pb isotope.
منابع مشابه
A gravimetric K2OsCl6 standard: Application to precise and accurate Os spike calibration
The Re-Os isotopic system is currently limited as a chronometer because of the lack of accurate gravimetric standards for Os spike calibration and uncertainty of the Re half-life, which is also dependent on the accuracy of Os spike calibration. We demonstrate that the concentration of an Os spike can be calibrated accurately to 60.2%. The accuracy of this calibration was achieved by using a hig...
متن کاملNatural fractionation of 238 U / 235 U
The isotopic composition of U in nature is generally assumed to be invariant. Here, we report variations of the U/U isotope ratio in natural samples (basalts, granites, seawater, corals, black shales, suboxic sediments, ferromanganese crusts/ nodules and BIFs) of 1.3‰, exceeding by far the analytical precision of our method ( 0.06‰, 2SD). U isotopes were analyzed with MC-ICP-MS using a mixed U–...
متن کاملMass-Independent and Mass-Dependent Ca Isotopic Compositions of Thirteen Geological Reference Materials Measured by Thermal Ionisation Mass Spectrometry
We report mass-independent and mass-dependent Ca isotopic compositions for thirteen geological reference materials, including carbonates (NIST SRM 915a and 915b), Atlantic seawater as well as ten rock reference materials ranging from peridotite to sandstone, using traditional e and d values relative to NIST SRM 915a, respectively. Isotope ratio determinations were conducted by independent unspi...
متن کاملS–S double spike thermal ionization mass spectrometry
dS and sulfate concentrations were determined in snow pit samples using a thermal ionization mass spectrometric technique capable of 0.2& accuracy and requires !5 lg (0.16 lmol) natural S. The technique utilizes a S–S double spike for instrumental mass fractionation correction, and has been applied to snow pit samples collected from the Inilchek Glacier, Kyrgyzstan and from Summit, Greenland. T...
متن کاملRevised delta34S reference values for IAEA sulfur isotope reference materials S-2 and S-3.
Revised delta(34)S reference values with associated expanded uncertainties (95% confidence interval (C.I.)) are presented for the sulfur isotope reference materials IAEA-S-2 (22.62 +/- 0.16 per thousand) and IAEA-S-3 (-32.49 +/- 0.16 per thousand). These revised values are determined using two relative-difference measurement techniques, gas source isotope ratio mass spectrometry (GIRMS) and dou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 863 شماره
صفحات -
تاریخ انتشار 2015