Tenax-TA extraction as predictor for free available content of polycyclic aromatic hydrocarbons (PAHs) in composted sewage sludges.

نویسنده

  • Patryk Oleszczuk
چکیده

The usability of the solid phase extraction method with Tenax-TA adsorbent for the forecasting of polycyclic aromatic hydrocarbon losses during sewage sludges composting has been evaluated in the present study. Four municipal sewage sludges were composted for 76 days. The PAH content in the sludges ranged from 3674 to 11 236 microg kg(-1). After composting, a significant reduction of PAH content was observed. The range of the PAH sum loss ranged from 29.3 to 48.6%. The share of fraction extracted by Tenax-TA in the sludges at the onset of the composting ranged from 28.1 to 54.0% in relation to the PAH sum, and from 0.31 to 100% for individual PAHs. After 76 days of composting, the presence of Tenax-TA extracted PAHs was still observed in the sludges. A significant reduction of this fraction was noted in the case of three sewage sludges. PAH's Tenax-TA fraction in the case of one sewage sludge did not undergo any changes during composting. A satisfactory prediction of PAH losses by the Tenax-TA method was rarely observed. The best reflection of the PAH losses was observed in the case of fluoranthene, anthracene and indeno[1,2,3-cd]pyrene.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

The potential of low temperature extraction method for analysis of polycyclic aromatic hydrocarbons in refined olive and refined pomace olive oils by HPLC/FLD

Background and Objectives: A method was developed and validated for determining 15 polycyclic aromatic hydrocarbons (PAHs) in refined olive and refined pomace olive oils using high performance liquid chromatography coupled with a fluorescence detector. Materials and Methods: The sample preparation involved liquid–liquid extraction with organic solvent and low temperature clean-up. The low temp...

متن کامل

Tenax as sorption sink for in vitro bioaccessibility measurement of polycyclic aromatic hydrocarbons in soils.

Physiologically based in vitro methods have been developed to measure bioaccessibility of organic contaminants in soils. However, bioaccessibility of hydrophobic organic contaminants (HOCs) can be underestimated by in vitro tests if gastrointestinal (GI) solution fails to provide sufficient sorption sink for HOCs. To circumvent this drawback, Tenax was included in GI solution as sorption sink t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental monitoring : JEM

دوره 10 7  شماره 

صفحات  -

تاریخ انتشار 2008