A cryogenic current comparator for beam diagnostics in the FAIR project

نویسندگان

  • A. Steppke
  • R. Geithner
  • R. Neubert
  • W. Vodel
  • H. Reeg
  • M. Schwickert
چکیده

A cryogenic current comparator(CCC) is based on the properties of ideal superconductors to expel magnetic flux from the bulk material through shielding currents on the surface of the material. As this effect is only dependent on the magnetic field, the CCC allows measuring the magnetic field, e.g. generated by a passing ion beam, they can be measured non-destructively with a high precision. In figure 1 the main components of a CCC are shown. The magnetic field of the beam current creates shielding currents on the superconducting magnetic ring structure, which are transformed with a torodial single turn pick-up coil and its ferromagnetic core. The signal from the pickup coil is feed to a LTS DC SQUID and measured via the external electronics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Cryogenic Current Comparator for Fair with Improved Resolution *

A Cryogenic Current Comparator is a highly sensitive tool for the non-destructive online monitoring of continuous as well as bunched beams of very low intensities. The noise-limited current resolution of such a device depends on the ferromagnetic material embedded in the pickup coil of the CCC. Therefore, the main focus of research was on the low temperature properties of ferromagnetic core mat...

متن کامل

Squid Based Cryogenic Current Comparator for Measurements of the Dark Current of Superconducting Cavities

A newly high performance SQUID based measurement system for detecting dark currents, generated by superconducting cavities for the upcoming X-FEL project at DESY Hamburg, is proposed. It makes use of the Cryogenic Current Comparator principle and senses dark currents in the pA range with a measurement bandwidth of up to 70 kHz.

متن کامل

Optimization of Particle Accelerators (opac)

The optimization of the performance of any particle accelerator critically depends on an in-depth understanding of the beam dynamics, powerful simulation tools and beam diagnostics, as well as a control and data acquisition system that links all the above. The oPAC consortium has carried out collaborative research into these areas, with the aim to optimize the performance of present and future ...

متن کامل

A Cryogenic Current Comparator for the Low-energy Antiproton Facilities at Cern

Several laboratories have shown the potential of Cryogenic Current Comparators (CCC) for an absolute measurement of beam intensity down to the nA level. This type of current monitor relies on the use of Superconducting QUantum Interference Device (SQUID) magnetometers and superconductor magnetic shields. CERN, in collaboration with GSI Helmholtz Centre for Heavy Ion Research, Jena University, a...

متن کامل

The Injector Systems of the Fair Project

The present GSI accelerator chain will serve as an injector for FAIR (Facility for Antiproton and Ion Research). The linear accelerator UNILAC and the heavy ion synchrotron SIS18 should deliver up to 1⋅10 U-particles/sec. In the past two years different hardware measures and a careful fine tuning of the UNILAC resulted in an 35% increase of the beam intensity to a new record of 1.25⋅10 U-ions...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008