Nanoparticle detection using dual-phase interferometry.
نویسندگان
چکیده
The detection and identification of nanoparticles is of growing interest in atmospheric monitoring, medicine, and semiconductor manufacturing. While elastic light scattering with interferometric detection provides good sensitivity to single particles, active optical components prevent scalability of realistic sizes for deployment in the field or clinic. Here, we report on a simple phase-sensitive nanoparticle detection scheme with no active optical elements. Two measurements are taken simultaneously, allowing the amplitude and phase to be decoupled. We demonstrate the detection of 25 nm Au particles in liquid in Δt ∼ 1 ms with a signal-to-noise ratio of ∼ 37. Such performance makes it possible to detect nanoscale contaminants or larger proteins in real time without the need of artificial labeling.
منابع مشابه
Measuring nanoparticle size using optical surface profilers.
Optical surface profilers are state-of-the-art instruments for measuring surface height profiles. They are not conventionally applied to nanoparticle measurements due to the presence of diffraction artifacts. Here we use a theoretical model based on wave-optics to account for diffraction-based artifacts in optical surface profilers. This then enables accurate measurement of nanoparticles size o...
متن کاملطراحی، ساخت و مشخصه یابی پله های فازی شیشه ای برای کاربرد در تداخل سنجی جابجایی فاز
In this paper, we report on the design and fabrication of a low-cost phase shifter for application in phase shifting interferometry. Phase shifting interferometry is a powerful method for surface characterization. It uses interference data recorded during a series of predetermined phase shifts to recover the induced phase by the object surface. These controlled phase shifts are typically perfor...
متن کاملAn anti-fouling aptasensor for detection of thrombin by dual polarization interferometry.
An anti-fouling surface was designed to effectively resist nonspecific protein adsorption using dual polarization interferometry, based on which the aptasensor for detection of thrombin was fabricated according to the specific interaction between thrombin and its 15-mer aptamer.
متن کاملIntegration of the atmospheric fluctuations in a dual-field optical interferometer: the short exposure regime
Spatial phase-referencing in dual-field optical interferometry is reconsidered. Our analysis is based on the 2-sample variance of the differential phase between target and reference star. We show that averaging over time of the atmospheric effects depends on this 2-sample phase variance (Allan variance) rather than on the true variance. The proper expression for fringe smearing beyond the isopl...
متن کاملThree-stage inversion improvement for forest height estimation using dual-PolInSAR data
This paper addresses an algorithm for forest height estimation using single frequency single baseline dual polarization radar interferometry data. The proposed method is based on a physical two layer volume over ground model and is represented using polarimetric synthetic aperture radar interferometry (PolInSAR) technique. The presented algorithm provides the opportunity to take advantages of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 49 26 شماره
صفحات -
تاریخ انتشار 2010