Effect of labor epidural anesthesia on breast-feeding of healthy full-term newborns delivered vaginally.

نویسندگان

  • Dennis J Baumgarder
  • Patricia Muehl
  • Mary Fischer
  • Bridget Pribbenow
چکیده

BACKGROUND Epidural anesthesia is commonly administered to laboring women. Some studies have suggested that epidural anesthesia might inhibit breast-feeding. This study explores the association between labor epidural anesthesia and early breast-feeding success. METHODS Standardized records of mother-baby dyads representing 115 consecutive healthy, full-term, breast-feeding newborns delivered vaginally of mothers receiving epidural anesthesia were analyzed and compared with 116 newborns not exposed to maternal epidural anesthesia. Primary outcome was two successful breast-feeding encounters by 24 hours of age, as defined by a LATCH breast-feeding assessment score of 7 or more of 10 and a latch score of 2/2. Means were compared with the Kruskal-Wallis test. Categorical data were compared using the Mantel-Haenszel chi-square test. Stratified analysis of potentially confounding variables was performed using Mantel-Haenszel weighted odd ratios (OR) and chi-square for evaluation of interaction. RESULTS Both epidural and nonepidural anesthesia groups were similar except maternal nulliparity was more common in the epidural anesthesia group. Two successful breast-feedings within 24 hours of age were achieved by 69.6% of mother-baby units that had had epidural anesthesia compared with 81.0% of mother-baby units that had not (odds ratio [OR] 0.53, P = .04). These relations remained after stratification (weighted odds ratios in parenthesis) based on maternal age (0.52), parity (0.58), narcotics use in labor (0.49), and first breast-feeding within 1 hour (0.49). Babies of mothers who had had epidural anesthesia were significantly more likely to receive a bottle supplement while hospitalized (OR 2.63; P < .001) despite mothers exposed to epidural anesthesia showing a trend toward being more likely to attempt breast-feeding in the 1 hour (OR 1.66; P = .06). Mothers who had epidural anesthesia and who did not breast-feed within 1 hour were at high risk for having their babies receive bottle supplementation (OR 6.27). CONCLUSIONS Labor epidural anesthesia had a negative impact on breast-feeding in the first 24 hours of life even though it did not inhibit the percentage of breast-feeding attempts in the first hour. Further studies are needed to elucidate the exact nature of this association.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neurobehavioral functioning and breastfeeding behavior in the newborn.

OBJECTIVE To determine whether central nervous system functioning has an effect on the normal, term infant's ability to breastfeed in the first day following birth. DESIGN Breastfeeding behaviors and neurobehaviors were evaluated at birth and at 24 hrs of age in two groups of neonates. One group of neonates was born to mothers who received epidural analgesia during labor, and one group was bo...

متن کامل

The effect of ultra low dose epidural analgesia on newborn breastfeeding behaviors.

OBJECTIVE To determine whether a difference in breastfeeding behaviors could be observed between newborns whose mothers received epidural analgesia for labor pain relief and those newborns whose mothers received no pain medication in labor. DESIGN There were two groups of neonates in this study. One group was born to mothers who received epidural analgesia, and one group was born to mothers w...

متن کامل

ارتباط اکسی توسین و پرومتازین تزریقی هنگام زایمان با هیپربیلی روبینمی روز سوم بعد از تولد

Background and Aim: Oxytocin causes restriction of water in newborns' red blood cells because of its hyposmotic potential. Therefore red blood cells' ability to change their form decreases, but their lysis increases when they pass through reticuloendothelial system which causes hyperbilirubinemia in the newborn. Promethazin, because of its efficacy against liver bile ducts, also causes reversib...

متن کامل

Effect of Epidural Anesthesia with Lidocaine and Bupivacaine on Gastrointestinal Transit Time in Healthy Dogs

Objective- To evaluate the effect of epidural anesthesia with lidocaine and bupivacaine on transit time of barium sulfate contrast medium through gastrointestinal (GI) tracts in healthy dogs. Design- Prospective, randomized experimental study. Animals-Five healthy mixed breed male dogs with 19.2±7.8 months age and 19.9±3.3 kg weight Procedure- The animals received one of the treatments of sa...

متن کامل

[Perinatal factors affecting the detection of otoacoustic emissions in vaginally delivered, healthy newborns, during the first 48 hours of life].

INTRODUCTION AND OBJECTIVES Most hospitals perform neonatal hearing screening because it is a very useful procedure. Otoacoustic emissions are an ideal technique for this screening. We analyse the possible influence on screening results of some perinatal factors. MATERIALS AND METHODS We collected retrospective data from 8,239 healthy newborns delivered vaginally at the maternity ward of our ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the American Board of Family Practice

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2003