BACKGROUND Between-assay comparability of 99th percentiles for cardiac troponin concentrations has not been assessed systematically in a single population for a large number of assays. METHODS We determined 99th percentiles for 19 cardiac troponin assays in heparin plasma samples from a population of 272 and 252 presumably healthy males and females, respectively. The assays evaluated included 1 cardiac troponin T (cTnT) assay from Roche and 18 cTnI assays from Abbott, Alere, Beckman, bioMerieux, Instrumentation Laboratory, Ortho-Clinical Diagnostics, Singulex, Siemens, and Roche. Five of these assays were categorized as high-sensitivity, 9 as sensitive-contemporary, and 5 as point-of-care (POC) assays. RESULTS For high-sensitivity cTnI (hs-cTnI) assays 99th percentiles varied from 23 to 58 ng/L. At least 80% of individuals had measurable hs-cTnI, whereas only 25% had measurable high-sensitivity cTnT. All high-sensitivity cardic troponin assays had 99th percentiles that were 1.2-2.4-fold higher in males than females. For the 9 sensitive-contemporary cTnI assays, 99th percentiles varied from 12 to 392 ng/L, and only the Beckman assay gave measurable concentrations in a substantial portion of the population (35% vs ≤6% for the others). Seven of these 9 assays had 1.3-5.0-fold higher 99th percentiles for males than females. For 5 cTnI POC assays, 99th percentiles varied from <10 to 40 ng/L. The Instrumentation Laboratory assay gave measurable results in 27.8% of study participants vs ≤6% for the others. Correlations were generally poor among assays. CONCLUSIONS Among cardiac troponin assays 99th percentile concentrations appear to differ. High-sensitivity assays provide measurable cardiac troponin results in a substantially greater fraction of presumably healthy individuals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the 99th percentile upper reference limit for high-sensitivity cardiac troponin I in Malaysian population.

Introduction of high-sensitivity cardiac troponin I (hscTn I) assays for routine clinical use in Malaysia requires determination of the 99th percentile upper reference limit (URL) for each assay to suit local context. Hence, this study aimed to determine the 99th percentile URL for hscTn I in the Malaysian population. A total of 250 (120 males and 130 females) healthy Malaysian blood donors age...

متن کامل

Influence of population selection on the 99th percentile reference value for cardiac troponin assays.

OBJECTIVE We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. METHODS Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The...

متن کامل

Longitudinal studies of cardiac troponin I in a large cohort of healthy children.

BACKGROUND There is little information available on cardiac troponin concentrations in healthy young children. METHODS Using a precommercial high-sensitivity assay from Abbott Diagnostics, we measured cardiac troponin I (cTnI) in longitudinal blood samples collected at ages 8, 10, and 12 years from a cohort of healthy, community-dwelling children. The 99th percentile values were calculated an...

متن کامل

Cardiac troponin scorecard.

The recent opinion paper by Apple (1 ) on a cardiac troponin assay scorecard has enhanced the conundrum on whether cardiac troponin assays are clinically usable or not. Apple has proposed a scorecard that evaluates cardiac troponin assays according to the total imprecision at the 99th percentile. The cited data include the concentrations at the 10% CV and whether the value is greater or less th...

متن کامل

99th percentile and analytical imprecision of troponin and creatine kinase-MB mass assays: an objective platform for comparison of assay performance.

Cardiac troponins in blood are the most sensitive and specific biochemical markers of myocardial damage and are paramount for classification, risk stratification, and customized therapy in patients with acute coronary syndromes (1, 2). Despite the overt advantages, some important obstacles to troponin analysis and interpretation have remained, such as assay standardization, interference, preana...

متن کامل

ذخیره در منابع من