Embolic protection devices.

نویسندگان

  • Sripal Bangalore
  • Deepak L Bhatt
چکیده

M anipulation of atherosclerotic lesions with wires, cath-eters, balloons, stents, and other intravascular devices during invasive procedures releases atherosclerotic plaque, resulting in distal embolization. This plaque debris leads to no or slow flow as a result of a multitude of factors, including mechanical obstruction of macrovascular and microvascu-lar channels, local platelet adhesion, platelet activation, and thrombosis attributable to release of tissue factors and micro-vascular spasm by release of thromboxane. The clinical manifestation of this shower of atherosclerotic debris depends on the characteristics: the amount of debris, the size of particles, and the sensitivity of the organ perfused. Distal embolization during percutaneous coronary intervention (PCI) results in decreased distal perfusion, leading to myocardial ischemia or infarction. Manipulation of the aortic arch during coronary, cerebral, or valvular procedures can cause microembolization to the cerebral circulation that may manifest as a transient ischemic attack or stroke. Distal embolization is seen during intervention of all vascular beds, including peripheral, renal, and mesenteric arteries, but the clinical manifestation varies and depends on the sensitivity of the organ perfused and the metric used to assess end-organ damage. Embolic protection devices (EPDs) prevent or reduce plaque debris from reaching the distal bed and thereby have the potential to reduce adverse clinical events. They are commonly used in saphenous vein graft (SVG) interventions and during carotid artery stenting procedures. They are also being tested in other vascular beds such as the renal arteries, but their utility at reducing clinically significant outcomes in these vascular beds has yet to be established. Hyperlinked to this article is a video demonstrating the use of EPDs. Downloadable slides about EPD are available in the online-only Data Supplement. EPDs can be divided into 3 distinct types based on their mechanism of operation: distal occlusion aspiration devices, distal filters, and proximal occlusion aspiration devices. Distal occlusion aspiration devices contain an inflatable occlusion balloon mounted on a hypotube (online-only Data Supplement, slide 23: Distal Protection–GuardWire). The balloon is passed several centimeters distal to the lesion and is inflated to obstruct antegrade flow with a carbon dioxide– filled syringe. This low-pressure balloon dilatation has been found not to increase the risk of restenosis, attesting to its safety. 1 The hypotube is used as the interventional guide wire for the balloon angioplasty or stenting. These devices work by occluding flow to create a column of stagnant blood that traps plaque debris and soluble debris that are subsequently …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Embolic Protection Devices in Transcatheter Aortic Valve Replacement

Abstract—The initially reported periprocedural neurological events rates associated with transcatheter aortic valve replacement raised concerns that ultimately led to the development and to the clinical research of novel embolic protection devices. Although the reduction of clinical stroke is a desired goal, the current research design of embolic protection devices focuses on surrogate markers ...

متن کامل

Role of adjunctive thrombectomy and embolic protection devices in acute myocardial infarction: a comprehensive meta-analysis of randomized trials.

AIMS Adjunctive thrombectomy and embolic protection devices in acute myocardial infarction have been extensively studied, although outcomes have mainly focused on surrogate markers of reperfusion. Therefore, the effect of adjunctive devices on clinical outcomes is unknown. This study sought to determine whether the use of a thrombectomy or embolic protection device during revascularization for ...

متن کامل

Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients.

BACKGROUND AND PURPOSE Periprocedural embolization of debris during carotid stenting interventions may result in neurological deficit. This study was designed to evaluate in-hospital and 30-day adverse events in patients percutaneously treated for carotid artery disease with embolic protection devices. METHODS From 1999 to June 2002, a total of 442 consecutive patients underwent percutaneous ...

متن کامل

Embolic protection and platelet inhibition during renal artery stenting.

BACKGROUND Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. METHODS AND RESULTS One hundred patients undergoing renal artery stenting at 7 ce...

متن کامل

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 129 17  شماره 

صفحات  -

تاریخ انتشار 2014