Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope.

نویسندگان

  • N Lois
  • A S Halfyard
  • C Bunce
  • A C Bird
  • F W Fitzke
چکیده

AIM To evaluate the reproducibility of the background fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. METHODS 10 normal volunteers and 10 patients with retinal disease were included in the study. One eye per subject was chosen randomly. Five images of the same eye of each individual were obtained, after pupillary dilatation, by two investigators using a confocal scanning laser ophthalmoscope. Background fundus autofluorescence was measured at 7 degrees temporal to the fovea in normal volunteers and between 7 and 15 degrees temporal to the fovea in patients. Within session reproducibility of the measurements obtained by each investigator and interobserver reproducibility were evaluated. RESULTS For investigator 1 the median values of fundus autofluorescence obtained were 31.9 units for normal volunteers and 27.3 units for patients. The median largest differences in readings in normal volunteers was 5.7 units (range 1.4-13.5 units) and in patients 4.2 units (1.5-15.1 units). For investigator 2 the median values of fundus autofluorescence obtained were 28.9 units for normal volunteers and 27.4 units for patients. The median largest difference in readings in normal volunteers was 3.6 units (2.7-11.7 units), and in patients 4.1 units (1.5-9.3 units). The median interobserver difference in readings in normal volunteers was 3.3 units and for patients 6.6 units. The median greatest interobserver difference in measurements obtained for normal volunteers was 8.8 units (8.4-23.0 units) and for patients 11.1 units (7.1-40.8 units). CONCLUSION Within session reproducibility of the measurements of background fundus autofluorescence was satisfactory. Although interobserver reproducibility was moderate, the variability of the measurements of fundus autofluorescence between observers appears to be small when compared with variation in fundus autofluorescence with age and disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fundus autofluorescence in patients with macular holes imaged with a laser scanning ophthalmoscope.

AIM To demonstrate the usefulness of a recently developed technique of imaging fundus autofluorescence and to compare it with the results of fluorescein angiography in the diagnosis and staging of macular holes. METHODS The intensity and distribution of fundus autofluorescence was studied in 51 patients with idiopathic macular holes and pseudoholes using a confocal laser scanning ophthalmosco...

متن کامل

Confocal fundus imaging with a scanning laser ophthalmoscope in eyes with cataract.

AIMS/BACKGROUND The study aimed to determine the influence of increased intraocular light scatter on the contrast in scanning laser ophthalmoscope (SLO) images and to examine to what extent SLO images can visualise the fundus through media opacities due to cataract. METHODS Intraocular light scatter was estimated from measurements of letter contrast sensitivity before and after cataract surge...

متن کامل

Quantitative measurements of autofluorescence with the scanning laser ophthalmoscope.

PURPOSE To evaluate the feasibility and reliability of a standardized approach for quantitative measurements of fundus autofluorescence (AF) in images obtained with a confocal scanning laser ophthalmoscope (cSLO). METHODS AF images (30°) were acquired in 34 normal subjects (age range, 20-55 years) with two different cSLOs (488-nm excitation) equipped with an internal fluorescent reference to ...

متن کامل

Fundus autofluorescence in age-related macular disease imaged with a laser scanning ophthalmoscope.

PURPOSE To image and quantify the spatial distribution of fundus autofluorescence in normal subjects, to determine its age dependence, and to document the deviation from normal in patients with age-related macular disease. METHODS Using a confocal laser scanning ophthalmoscope (cLSO), the intensity and spatial distribution of fundus autofluorescence was studied in 33 normal subjects, 97 eyes ...

متن کامل

Simultaneous Confocal Scanning Laser Ophthalmoscopy Combined with High-Resolution Spectral-Domain Optical Coherence Tomography: A Review

We aimed to evaluate technical aspects and the clinical relevance of a simultaneous confocal scanning laser ophthalmoscope and a high-speed, high-resolution, spectral-domain optical coherence tomography (SDOCT) device for retinal imaging. The principle of confocal scanning laser imaging provides a high resolution of retinal and choroidal vasculature with low light exposure. Enhanced contrast, d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 3  شماره 

صفحات  -

تاریخ انتشار 1999