Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test.

نویسندگان

  • Ho-Joong Kim
  • Seung Hoo Lee
  • Bong-Soon Chang
  • Choon-Ki Lee
  • Teck Onn Lim
  • Ling Ping Hoo
  • Je-Min Yi
  • Jin S Yeom
چکیده

STUDY DESIGN Prospective randomized controlled trial. OBJECTIVE The aim of this study was to monitor the quality control of robot-assisted pedicle screw fixation accuracy by using a cumulative summation (CUSUM) test at the initial stage of its application. SUMMARY OF BACKGROUND DATA Although robot-assisted pedicle screw fixation reduces screw misplacement rates and provides critical support for minimally invasive surgical procedures, there have been no reports relating to the monitoring of quality control of the accuracy of this robot-assisted pedicle screw fixation procedure. METHODS Patients with lumbar spinal stenosis scheduled to undergo surgery were randomly and equally assigned through 1:1 allocation to a robot-assisted minimally invasive posterior lumbar interbody fusion (Rom-PLIF) group or a conventional open posterior PLIF using freehand technique group. The accuracy of pedicle screw placement was evaluated using postoperative computed tomography. The primary outcome was the CUSUM analysis for monitoring the quality control of the accuracy of pedicle screw insertion between the Rom-PLIF and conventional open posterior PLIF using freehand technique groups. RESULTS Of the 80 pedicle screws inserted in each group, 4 screws in the Rom-PLIF group, and 7 in the conventional open PLIF group, breached the pedicle. Of these 11 offending screws, 4 cases were categorized as grade B in the Rom-PLIF group, whereas 6 were grade B and 1 case was grade C in the Com-PLIF group, using the Gertzbein and Robbins classification. Throughout the monitoring period, there was no CUSUM test-derived indication that the quality of performance of the pedicle screw fixation procedure was inadequate in either group. CONCLUSION First, this study demonstrates the adequacy of quality control of robot-assisted pedicle screw fixation even early in the application period based on the CUSUM analysis. Second, the CUSUM test can be a useful tool for monitoring of the quality of procedures related with spine surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Computed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures.

BACKGROUND Incorrect placement of pedicle screws may lead to neurovascular injury, so the position is important for the reduction of spinal fractures. CT-based image-guided surgery has been promoted as a means to theoretically improve the accuracy of pedicle screw placement. Patients who underwent CT-based navigation-assisted pedicle screw fixation for thoracic or lumbar fractures were reviewed...

متن کامل

The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients

OBJECTIVE This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. MET...

متن کامل

Comparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages

INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...

متن کامل

Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.

STUDY DESIGN An in vitro biomechanical study to compare 2 different dorsal screw fixation techniques in the cervical spine with respect to primary stability and stability after cyclic loading. OBJECTIVES To investigate if the biomechanical stability is better in pedicle screw or in lateral mass fixation. SUMMARY OF BACKGROUND DATA In patients with poor bone quality who require multisegmenta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2015