Impedances and Power Losses for an Off-axis Beam
نویسنده
چکیده
A method for calculating coupling impedances and power losses for off-axis beams is developed. It is applied to calculate impedances of small localized discontinuities like holes and slots, as well as the impedance due to a finite resistivity of chamber walls, in homogeneous chambers with an arbitrary shape of the chamber cross section. The approach requires to solve a two-dimensional electrostatic problem, which can be easily done numerically in the general case, while for some particular cases analytical solutions are obtained.
منابع مشابه
Beam-ion confinement for different injection geometries
The DIII-D tokamak is equipped with neutral beam sources that inject in four different directions; in addition, the plasma can be moved up or down to compare off-axis with on-axis injection. Fast-ion data for eight different conditions have been obtained: co/counter, near-tangential/near-perpendicular and on-axis/off-axis. Neutron measurements during short beam pulses assess prompt and delayed ...
متن کاملImpedance Budget for the Kek B-factory
In this paper, we deal with impedances of various beamline elements in the KEK B-Factory. We will also discuss the power deposition generated by a beam in the form of the higher-ordermode (HOM) losses by interacting with its surroundings.
متن کاملCoupling Impedances of Muffin–tin Structures with Closed and Open Sides
In a previous work the eigenmodes of a muffin–tin structure limited with lateral electric walls were calculated using the mode matching technique. Now a modulated off axis beam is introduced and the beam induced fields, as well as the longitudinal coupling impedances are calculated. Furthermore, in order to get the fields in case of the open structure, the discrete set of modes in the field exp...
متن کاملAn Approximate Solution of Functionally Graded Timoshenko Beam Using B-Spline Collocation Method
Collocation methods are popular in providing numerical approximations to complicated governing equations owing to their simplicity in implementation. However, point collocation methods have limitations regarding accuracy and have been modified upon with the application of B-spline approximations. The present study reports the stress and deformation behavior of shear deformable functionally grad...
متن کاملMeasurement of stereotactic beam data of 9 MV X-rays using diode detector
Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...
متن کامل