Absolute quantification of activity content from PET images using the Philips Gemini TF PET/CT system.

نویسندگان

  • M Sydoff
  • H Uusijärvi
  • S Leide-Svegborn
  • S Mattsson
چکیده

Positron emission tomography combined with computed tomography (PET/CT) is a quantitative technique suitable for diagnostics and uptake measurements. The quantitative results can be used for the purpose of the calculating absorbed dose to patients undergoing nuclear medicine investigations. Hence, the accuracy of the quantification of the activity content in organs or tissues is of great importance. When using a planar gamma camera and single photon emission computed tomography (SPECT) images, the activity content in organs and tumours has to be determined by the user, using the number of counts in the organs and the efficiency of the camera. However, when using a Philips Gemini TF PET/CT system, the activity concentration in a region of interest (ROI) is given by the system. The reliability of activity concentration values given by the Philips Gemini TF PET/CT system was studied using a Jaszczak phantom containing hot spheres of different sizes; the influence of the ROI size and the impact of organ size, that is the partial volume effect, was investigated with three different lesion-to-background ratios in the phantom. The use of a small ROI size (40 % of the large ROI size, which covered the entire sphere) showed a 15 % improvement in the recovery of the true activity. Small lesion sizes result in large underestimations of the activity concentration values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of using different reconstruction algorithms on sensitivity of quantitative 18F-FDG-PET volumetric measures to background activity variation

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

متن کامل

Cardiac MRI and FDG-PET in the diagnosis of cardiac sarcoidosis

Methods 30 patients meeting Japanese Ministry of Health & Welfare guidelines [2] for clinical cardiac sarcoidosis were investigated with FDG-PET CT (Gemini TF Philips) and CMRI (Aera 1.5T Siemens) on the same day. Patients undergoing FDG-PET followed a 24 hour low-carbohydrate diet and overnight fast [3]. CMRI examination included SSFP assessment of left ventricular (LV) function, short axis T2...

متن کامل

Use of segmented CT transmission map to avoid metal artifacts in PET images by a PET-CT device

BACKGROUND: Attenuation correction is generally used to PET images to achieve count rate values independent from tissue densities. The goal of this study was to provide a qualitative comparison of attenuation corrected PET images produced by a PET-CT device (CT, 120 kV, 40 mAs, FOV 600 mm) with and without segmentation of transmission data (ACseg+ and ACseg-respectively). Methods: The reconstru...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 139 1-3  شماره 

صفحات  -

تاریخ انتشار 2010