Estimation of HVDC Partial Discharge Incident Occurrences

نویسنده

  • Joydeep Sarkar
چکیده

Similar to AC system, the insulation system of DC system also gets affected. The HVDC station is a challenging environment for measurement of partial discharge level due to very high interference levels caused from the switching of thyristor-controlled converters. There is also significant interference from external air-corona due to high electric stress at the surface of conductors and hardware that exceeds the corona inception level. In this review, lets us look at the scenario of HVDC system getting affected by partial discharge with methods of measuring it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of HVDC System to Improve Estimation of Transient DC Current and Voltages for AC Line-to-Ground Fault—An Actual Case Study in Korea

A new modeling method for high voltage direct current (HVDC) systems and associated controllers is presented for the power system simulator for engineering (PSS/E) simulation environment. The aim is to improve the estimation of the transient DC voltage and current in the event of an AC line-to-ground fault. The proposed method consists primary of three interconnected modules for (a) equation co...

متن کامل

Role of Ion Sources for Spacer Charging in SF6 Gas Insulated HVDC Systems

Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model ...

متن کامل

Evaluation of SARIMA time series models in monthly streamflow estimation in Idanak hydrometry station

prediction of hydrological variables is a highly effective tool in water resource management. One of the important tools for modeling hydrological processes is the use of time series modeling and analysis. River series production series can be used by time series models in various studies such as drought, flood, reservoir systems design and many other purposes For this purpose, monthly flow dat...

متن کامل

Remote Detection and Recognition of Electrostatic Discharge from HVDC Transmission Lines

To remotely detect corona discharge from High-Voltage Direct Current (HVDC) transmission lines, a detecting system combining detecting platform and data progressing system is designed. Detecting platform is developed resorting to the principle of differential noise reduction, which can fulfill narrow-band detection breaking away interference from broadcasting and easily catch the electrostatic ...

متن کامل

Self-Adaptive Morphological Filter for Noise Reduction of Partial Discharge Signals

Partial Discharge assessment in the insulation of high voltage equipment is one of the most popular approaches for prevention of the insulation breakdown. In the procedure of thisassessment, noise reduction of partial discharge signals to get the original PD signal for accurate evaluation is inevitable. This denoising process shall be carried out such a way that the main features of the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014