Intracranial vessel wall imaging with simultaneous blood and CSF suppression
نویسندگان
چکیده
Introduction: Recent studies suggested that the intracranial artery disease may have contributed to stroke and other clinical events more often than previous believes. Although non-invasive MR techniques have long been used to evaluate the extracranial arteries’ plaque burden and components, only a few techniques are at the clinicians’ deploy when studying the intracranial artery. One of the key reasons is that the successful delineation of intracranial artery outer wall boundary requires the simultaneous suppression of blood and cerebrospinal fluid (CSF). The two requirements are usually competing and it’s challenging to achieve both in a time-efficient fashion. Previous techniques are limited either by low-efficiency or the lack of a dedicated CSF suppression. In this study, a fast intracranial wall imaging technique with simultaneous blood and CSF suppression was developed and tested in vivo. Methods: The pulse sequence diagram is shown in Fig.1. It contains a DANTE pre-pulse and a long echo train extended TSE (VISTA) acquisition: the DANTE pulse is used to saturate CSF and blood while the VISTA acquisition will also contribute to effective blood nulling. To achieve the most effective wall-CSF contrast, TR and flip angle (FA) were optimized using a signal model proposed before. In this simulation, flip angle ranges 1o50o and TR ranges 1-8ms were tendered to identify the optimized parameter. The number of TRs was adjusted to keep the total time of preparation (n×TR) constant. To evaluate the CSF nulling efficiency, 3 healthy volunteers were scanned after obtaining their informed consent. All scans were performed on a 3T whole body scanner (Philips Achieva, R3.21, the Netherlands). The proton density weighted VISTA acquisition was similarly configured as reported before: TR/TE 2000/19ms, FOV 210×180×48mm, voxel size 0.6×0.6×0.6mm, ETL 38, half scan, SENSE 2.8. Total scan time: 4min30sec. The DANTE prepared sequence used optimized parameters as identified in the simulation and matched acquisition parameters to VISTA. To evaluate the performance of DANTE’s performance on a multi-contrast imaging protocol, it was also added and compared to a regular 2D T2 TSE sequence (where CSF is expected to be bright). The imaging parameters were: TR/TE 4000/80ms, FOV 220×220mm, voxel size 0.6×0.6mm, slice thickness 4mm, ETL 12, scan time: 3min40sec for 16 slices. Results: As shown in Fig.2, the simulation indicates that shorter TR provides better contrast between vessel wall and CSF, and maximized contrast will be achieved when TR is 1ms and FA is 12o. In vivo tests found that DANTE VISTA demonstrated effective CSF suppression and helped greatly in visualizing the outer boundary of the intracranial artery (Fig.3), without compromising the scanning efficiency. In regular VISTA, the outer wall boundary of basilar artery couldn’t be visualized due to the similar contrast from CSF; while in DANTE, the outer wall can be better delineated as the CSF is much better suppressed. No apparent flow artifacts were identified on either set of the images. Similarly, in the traditional T2 TSE (Fig.4), although the overall image contrast was kept the same, DANTE was able to effectively eliminate the bright signal from CSF, making the vessel wall much better visualized. Conclusion: In this study, simultaneous blood and CSF suppression was achieved by taking the advantage of long T1 saturation of DANTE and the high acquisition efficiency of VISTA. The technique was optimized for CSF suppression and tested in vivo. It has been shown to suppress the CSF signal effectively on both proton density and T2 weighted images. This technique essentially provides an effective way to achieve multi-contrast intracranial atherosclerosis imaging, creating a unique solution to study the clinical impact of intracranial artery disease.
منابع مشابه
Improved black-blood imaging using DANTE-SPACE for combined carotid and intracranial vessel wall evaluation
Background Variable flip angle 3D TSE (SPACE) is a promising technique for vessel wall imaging that provides high resolution and the freedom of 3D retrospective formatting compared with 2D TSE. However it is difficult to completely suppress residual luminal blood which may mimic plaque leading to difficulties in diagnosis [Fan. JMRI. 2010:31], especially after contrast enhancement (CE). Additio...
متن کاملAdministration of recombinant human granulocyte colony-stimulating factor (rhG-CSF) for the intracranial hemorrhage in two dogs: a case report
Two dogs with generalized seizures were evaluated. The dogs were diagnosed with traumatic intracranial hemorrhages based on the history, neurological examinations, and magnetic resonance imaging (MRI) of the brain. Treatment was started with oxygen, prednisolone and anticonvulsant agents. No further seizure activity was observed after treatment in both dogs, however cushing reflex was detected ...
متن کاملVessel wall imaging for intracranial vascular disease evaluation.
Accurate and timely diagnosis of intracranial vasculopathies is important owing to the significant risk of morbidity with delayed and/or incorrect diagnosis both from the disease process and inappropriate therapies. Conventional luminal imaging techniques for analysis of intracranial vasculopathies are limited to evaluation of changes in the vessel lumen. Vessel wall MRI techniques can allow di...
متن کاملSpontaneous Intracranial Hypotension Plus Cerebral Venous Thrombosis: A Case Report Study
This is a case study of a 34-year-old woman who was admitted to hospital with a history of severe orthostatic headache. She was diagnosed as having spontaneous intracranial hypotension (SIH) by undetectable cerebrospinal fluid (CSF) pressure at lumbar puncture, and with evidence of diffuse dural enhancement of the brain detected by magnetic resonance imaging (MRI). However, the contrast-enhance...
متن کاملHigh Resolution 3D Intracranial Imaging at 3.0T
Introduction Vessel wall imaging of intracranial arteries is challenging due to their small sizes and their relatively deep locations inside the brain. 3D Time-of-flight (TOF) and contrast enhanced MRA (ceMRA) are commonly used [1] luminographic techniques. They lack specificity as luminal defects may be caused by various reasons. Dark blood, two dimensional turbo spin echo (2DTSE) has been use...