An Ionizing Radiation Sensor Using a Pre-Programmed MAHAOS Device
نویسندگان
چکیده
Metal-aluminum oxide-hafnium aluminum oxide-silicon oxide-silicon (hereafter MAHAOS) devices can be candidates for ionizing radiation sensor applications. In this work, MAHAOS devices (SONOS-like structures with high k stack gate dielectric) were studied regarding the first known characterization of the ionization radiation sensing response. The change of threshold voltage V(T) for a MAHAOS device after gamma ray exposure had a strong correlation to the total ionization dose (TID) of gamma radiation up to at least 5 Mrad TID. In this paper, the gamma radiation response performances of the pre-programmed and virgin (non-pre-programmed) MAHAOS devices are presented. The experimental data show that the change of VT for the pre-programmed MAHAOS device with gamma irradiation is very significant. The data of pre-programmed MAHAOS devices written by 5 Mrad TID of gamma radiation was also stable for a long time with data storage. The sensing of gamma radiation by pre-programmed MAHAOS devices with high k stack gate dielectric reported in this study has demonstrated their potential application for non-volatile ionizing radiation sensing technology in the future.
منابع مشابه
Detection of ionizing radiation emitted from the cesium-137 and cobalt-60 sources using electrochemical superoxide anion sensor in the aqueous medium
Widespread use of ionizing radiation in medicine, industry, agriculture, education and research, the increasing production of nuclear waste and nuclear incidents, has exposed humans and organisms to this radiation. Despite the benefits of ionizing radiation, these beams can cause serious damage to living systems. Hence, the need for radiation protection actions requires accurate, fast, inexpens...
متن کاملDesign and Characterization of Ionizing Radiation-Tolerant CMOS APS Image Sensors up to 30 Mrd (Si) Total Dose
An ionizing radiation-tolerant CMOS active pixel sensor (APS) image sensor test chip was designed employing the physical design techniques of enclosed geometry and -channel guard rings. The test chip was fabricated in a standard 0.35m CMOS process that has a gate-oxide thickness of 7.0 nm. It was irradiated by a -ray source up to a total ionizing radiation dose level of approximately 30 Mrd (Si...
متن کاملA New Stethoscope Design with Unique Characteristics and Development in Medical Device
As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases an...
متن کاملMeasuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry
Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...
متن کاملLET Estimation of Heavy Ion Particles based on a Timepix- Based Si Detector
Linear Energy Transfer (LET) is a measure of the energy transferred into a material as an ionizing particle passes through it. This quantity is useful in estimating the biological effects of ionizing radiation as expressed in dosimetric endpoints such as Dose-equivalent. Pixel detectors with silicon sensors --like the Medipix2 Collaboration’s Timepix-based devices-are ideal instruments to measu...
متن کامل