In-vivo assessment of barbed suturing thread with regard to tissue reaction and material absorption in a rat model
نویسندگان
چکیده
AIM The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. METHODS The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats' scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. RESULTS All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. CONCLUSION The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings.
منابع مشابه
Biocompatibility of eight different orthodontic materials: in-vivo rat model study
Biocompatibility of eight different orthodontic materials: in-vivo rat modl study Dr. Sadeghian, S.* - Dr. Razavi, S.M. ** - Dr. Masaeli, A.*** *Assistant Professor of Orthodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim: Differe...
متن کاملBiocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model
Biocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model Dr. Zare Jahromi, M.* - Dr. Razavi, S.M.** - Dr. Tabesh, B.*** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim...
متن کاملComparison of inflammatory response to polyglytone 6211 and polyglecaprone 25 in a rat model.
972 The aim of this study was to compare polyglytone 6211 (Caprosyn) and polyglecaprone 25 (Monocryl) in intracuticular skin closure in a rat model. The inflammatory response to these two suturing materials was assessed. Comparative studies involving polyglytone 6211 could not be found, and little is known about the wound-healing properties of polyglytone 6211. Caprosyn is a new absorbable, syn...
متن کاملThe Comparison of Oral Mucosal Clinical Reactions to PVDF and Silk Sutures in Albino Rabbit
This study was carried out in order to compare the oral mucosal reactions to silk and poly vinylidene fluoride (PVDF) suture materials in albino rabbit. Twenty-one mature male albino rabbits were selected and under general and local anesthesia suture materials were placed randomly at right and left side of vestibular area of maxillary jaw. The animals were divided into three equal groups based ...
متن کاملThe "Barbed Roman Blinds" technique: a step forward
Dear Editor, The recently developed “roman Blinds” technique, firstly described a few months ago in this journal, whose main appeals consist in lack of resection, reversibility, repeatability, low cost and minimal discomfort, appears to be effective in the treatment of snorers and patients with mild obstructive sleep apnoea . The technique achieves the widening and stiffening of the meso-pharyn...
متن کامل