Validated chromatographic methods for determination of perindopril and amlodipine in pharmaceutical formulation in the presence of their degradation products.
نویسندگان
چکیده
Two specific, sensitive, and precise stability-indicating chromatographic methods have been developed, optimized and validated for determination of perindopril arginin (PER) and amlodipine besylate (AML) in their mixtures and in the presence of their degradation products. The first method was based on thin-layer chromatography (TLC) combined with densitometric determination of the separated bands. Adequate separation was achieved using silica gel 60 F254 TLC plates and ethyl acetate-methanol-toluene-ammonia solution, 33% (6.5:2:1:0.5 by volume), as a developing system. The second method was based on high-performance liquid chromatography, by which the proposed components were separated on a reversed-phase C18 analytical column using a mobile phase consisting of phosphate buffer (pH 2.5, 0.01 M)-acetonitrile-tetrahydrofuran (60:40:0.1% by volume) with ultraviolet detection at 218 nm. Different parameters affecting the suggested methods were optimized for maximum separation of the cited components. System suitability parameters of the two developed methods were also tested. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for the quantification of PER and AML in their commercial tablets. Both methods were also statistically compared to each other and to the reference methods with no significant differences in performance.
منابع مشابه
Method development and validation of HPLC tandem/mass spectrometry for quantification of perindopril arginine and amlodipine besylate combination in bulk and pharmaceutical formulations
A well-characterized and fully validated ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometric (UHPLC-ESI-MS/MS) method was developed to reliably analyze combination of perindopril arginine and amlodipine besylate in bulk and tablet formulations. The chromatographic separation was achieved on a Waters ACQUITY UPLC® BEH C18 column with 1.7 μm particle pac...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملThermo-, Radio- and Photostability of Perindopril Tert-butyloamine in The Solid State. Comparison to Other Angiotensin Converting Enzyme Inhibitors
The main aim of this study was determination of thermo- radio- and photostability ofperindopril tert-butyloamine (PER) therefore the efficiency and safety of the therapy could bemaintained.A chromatographic method (RP-HPLC) had been validated before use to determinePER loss. The evaluation of stability properties of PER in solid state under the influence ofisothermal condition, relative humidit...
متن کاملThermo-, Radio- and Photostability of Perindopril Tert-butyloamine in The Solid State. Comparison to Other Angiotensin Converting Enzyme Inhibitors
The main aim of this study was determination of thermo- radio- and photostability ofperindopril tert-butyloamine (PER) therefore the efficiency and safety of the therapy could bemaintained.A chromatographic method (RP-HPLC) had been validated before use to determinePER loss. The evaluation of stability properties of PER in solid state under the influence ofisothermal condition, relative humidit...
متن کاملValidated Chromatographic Methods for Simultaneous Determination of Amlodipine Besylate and Perindopril Arginine in Binary Mixtures and in Pharmaceutical Dosage Form
The developed RP-HPLC depends on quantitative chromatographic separation of the studied drugs on a C18 column using phosphate Buffer:acetonitrile (60:40, v/v), pH=4.6 as a mobile phase delivered at constant flow rate of 1 mL.min-1 with UV detection at 210 nm. Calibration curves for Amlodipine besylate and Perindopril Arginine were constructed over the concentration range of 1-50 μg.mL-1 for bot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatographic science
دوره 51 6 شماره
صفحات -
تاریخ انتشار 2013