Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty.

نویسندگان

  • Pascal Boileau
  • Duncan Watkinson
  • Armodios M Hatzidakis
  • Istvan Hovorka
چکیده

This clinical study was performed to analyze the midterm results and potential complications of the reverse prosthesis in different diagnosis. Forty-five consecutive patients with Grammont prosthesis were evaluated clinically and radiographically with a mean follow-up of 40 months (range, 24-72 months). The indication was a massive and irreparable cuff tear associated with arthrosis (CTA) in 21 cases, fracture sequelae (FS) with arthritis in 5 cases, and failure of a revision arthroplasty (revision) in 19 cases. Fourteen complications occurred in 11 patients. 3 dislocations, 3 deep infections (all 3 in the revision group), 1 case of aseptic humeral loosening, 2 periprosthetic humeral fractures, 1 intraoperative glenoid fracture, 1 wound hematoma, 2 late acromial fractures, and 1 axillary nerve palsy. Of the patients, 10 (22%) required further surgery: 4 reoperations, 4 prosthesis revisions, and 2 prosthesis removals. Complications were higher in revision than in CTA (47% vs. 5%). All 3 groups showed a significant increase in active elevation (from 55 degrees preoperatively to 121 degrees postoperatively) and Constant score (from 17 to 58 points) but no significant change in active external rotation (from 7 degrees to 11 degrees ) or internal rotation (S1 preoperatively and postoperatively). Of the patients, 78% were satisfied or very satisfied with the result and 67% had no or slight pain. However, the postoperative Constant score, adjusted Constant score, and American Shoulder and Elbow Surgeons shoulder score were all significantly higher in the CTA group with as compared with the revision group (P = .01, .004, and .002, respectively). Scapular notching was seen in 24 cases (68%). No glenoid loosening was observed at current follow-up, even when the notch extended beyond the inferior screw (28% of cases). Atrophy of severe fatty infiltration of the teres minor was associated with lower external rotation (15 degrees vs 0 degrees , P = .02) and lower functional results (Constant score of 46 points vs 66 points, P < .007). The Grammont reverse prosthesis can improve function and restore active elevation in patients with incongruent cuff-deficient shoulders; active rotation is usually unchanged. Results are less predictable and complication and revision rates are higher in patients undergoing revision surgery as compared with those in patients with CTA. Results of the reverse prosthesis depend on the diagnosis and on the remaining cuff muscles, specifically the teres minor. Surgeons should be vigilant with regard to low-grade infection in revision surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uncommon Indications for Reverse Total Shoulder Arthroplasty

Total shoulder arthroplasty and shoulder hemiarthroplasty have been the traditional method for treating a variety of shoulder conditions, including arthritis, cuff tear arthropathy, and some fracture types. However, these procedures did not provide consistently good results for patients with torn rotator cuffs. The development of the reverse prosthesis by Grammont in the late 20th century revol...

متن کامل

Reverse Shoulder Arthroplasty Indications, Technique, and Results

The surgical treatment of glenohumeral arthritis with rotator cuff deficiency is a difficult challenge. Hemiarthroplasty, the standard treatment at this time, is associated with satisfactory results in a ‘‘limited goals’’ perspective, but often the clinical results are unpredictable. Elevation after hemiarthroplasty approximately 90 . Pain relief can be inconsistent and can deteriorate over tim...

متن کامل

Recent advances in shoulder arthroplasty

Prosthetic shoulder arthroplasty is becoming increasingly popular. The most widely reported procedures are hemiarthroplasty and unconstrained total arthroplasty using the Neer II prosthesis, which involves insertion of a press-fit or cemented humeral component and a cemented polyethylene glenoid implant. Long-term studies show that excellent or good results are achieved in over 90% of cases, wi...

متن کامل

Reversed shoulder arthroplasty in cuff tear arthritis, fracture sequelae, and revision arthroplasty

BACKGROUND AND PURPOSE Reversed shoulder arthroplasty may be used for severe arthropathy where conventional prostheses cannot restore the function sufficiently. We analyzed the medium-term results and potential complications of the reversed prostheses, and also the influence of etiology on the result. METHODS; 52 women and 7 men, average age 70 (60-82) years, were followed for mean 4 (2-7) year...

متن کامل

Reverse total shoulder arthroplasty: a review of results according to etiology.

BACKGROUND Reverse total shoulder arthroplasty provides a surgical alternative to standard total shoulder arthroplasty for the treatment of selected complex shoulder problems. The purpose of the present study was to evaluate the effects of etiology on the results of reverse total shoulder arthroplasty. METHODS Between May 1995 and June 2003, 240 consecutive reverse total shoulder arthroplasti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2006