Automated method for the isolation of collecting ducts.

نویسندگان

  • R Lance Miller
  • Ping Zhang
  • Tong Chen
  • Andreas Rohrwasser
  • Raoul D Nelson
چکیده

The structural and functional heterogeneity of the collecting duct present a tremendous experimental challenge requiring manual microdissection, which is time-consuming, labor intensive, and not amenable to high throughput. To overcome these limitations, we developed a novel approach combining the use of transgenic mice expressing green fluorescent protein (GFP) in the collecting duct with large-particle-based flow cytometry to isolate pure populations of tubular fragments from the whole collecting duct (CD), or inner medullary (IMCD), outer medullary (OMCD), or connecting segment/cortical collecting duct (CNT/CCD). Kidneys were enzymatically dispersed into tubular fragments and sorted based on tubular length and GFP intensity using large-particle-based flow cytometry or a complex object parametric analyzer and sorter (COPAS). A LIVE/DEAD assay demonstrates that the tubules were >90% viable. Tubules were collected as a function of fluorescent intensity and analyzed by epifluorescence and phase microscopy for count accuracy, GFP positivity, average tubule length, and time required to collect 100 tubules. Similarly, mRNA and protein from sorted tubules were analyzed for expression of tubule segment-specific genes using quantitative real-time RT-PCR and immunoblotting. The purity and yield of sorted tubules were related to sort stringency. Four to six replicates of 100 collecting ducts (9.68+/-0.44-14.5+/-0.66 cm or 9.2+/-0.7 mg tubular protein) were routinely obtained from a single mouse in under 1 h. In conclusion, large-particle-based flow cytometry is fast, reproducible, and generates sufficient amounts of highly pure and viable collecting ducts from single or replicate animals for gene expression and proteomic analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Automated method for the isolation of collecting ducts

Miller, R. Lance, Ping Zhang, Tong Chen, Andreas Rohrwasser, and Raoul D. Nelson. Automated method for the isolation of collecting ducts. Am J Physiol Renal Physiol 291: F236–F245, 2006. First published February 7, 2006; doi:10.1152/ajprenal.00273.2005.—The structural and functional heterogeneity of the collecting duct present a tremendous experimental challenge requiring manual microdissection...

متن کامل

PERFORMANCE-BASED SEISMIC DESIGN OPTIMIZATION FOR MULI-COLUMN RC BRIDGE PIERS, CONSIDERING QUASI-ISOLATION

In this paper an optimization framework is presented for automated performance-based seismic design of bridges consisting of multi-column RC pier substructures. The beneficial effects of fusing components on seismic performance of the quasi-isolated system is duly addressed in analysis and design. The proposed method is based on a two-step structural analysis consisting of a linear modal dynami...

متن کامل

Analysis of fully developed flow and heat transfer through n-sided polygonal ducts with round corners using the Galerkin weighted residual method

The Galerkin weighted residuals method is extended solve the laminar, fully developed flow and heat transfer of Al2O3-water nanofluid inside polygonal ducts with round corners for the constant heat flux and uniform wall temperature boundary conditions. Using the method, semi-analytical, closed-form solutions are obtained for the friction coefficient and the Nusselt number in terms of the radius...

متن کامل

Endothelin A receptor-like immunoreactivity on the basal infoldings of rat renal tubules and collecting ducts.

We investigated the distribution of endothelin A (ET(A)) receptor-like immunoreactivity in the rat kidney using affinity-purified antibodies against amino acid residues 403-417 of the rat ET(A) receptor modified by the multiple antigen peptide complex system. Western blot analysis using the affinity-purified anti-ET(A) antibody detected bands of approximately 47.3 and 64.5 kDa in the rat kidney...

متن کامل

Thermal Development for Ducts of Arbitrary Cross Sections by Boundary-Fitted Coordinate Transformation Method

The non-orthogonal boundary-fitted coordinate transformation method is applied to the solution of steady three-dimensional momentum and energy equations in laminar flow to obtain temperature field and Nusselt numbers in the thermal entry region of straight ducts of different cross sectional geometries. The conservation equations originally written in Cartesian coordinates are parabolized in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Renal physiology

دوره 291 1  شماره 

صفحات  -

تاریخ انتشار 2006