Kinetic spectrophotometric method for determination of amlodipine besylate in its pharmaceutical tablets

نویسندگان

  • Ashraf M. Mahmoud
  • Hanaa M. Abdel-Wadood
  • Niveen A. Mohamed
چکیده

A simple and sensitive kinetic spectrophotometric method has been developed and validated for determination of amlodipine besylate (AML). The method was based on the condensation reaction of AML with 7-chloro-4-nitro-2,1,3-benzoxadiazole in an alkaline buffer (pH 8.6) producing a highly colored product. The color development was monitored spectrophometrically at the maximum absorption λmax 470 nm. The factors affecting the reaction were studied and the conditions were optimized. The stoichiometry of the reaction was determined, and the reaction pathway was postulated. Moreover, both the activation energy and the specific rate constant (at 70 °C) of the reaction were found to be 6.74 kcal mole-1 and 3.58 s-1, respectively. The initial rate and fixed time methods were utilized for constructing the calibration graphs for the determination of AML concentration. Under the optimum reaction conditions, the limits of detection and quantification were 0.35 and 1.05 μg/mL, respectively. The precision of the method was satisfactory; the relative standard deviations were 0.85-1.76%. The proposed method was successfully applied to the analysis of AML in its pure form and tablets with good accuracy; the recovery percentages ranged from 99.55±1.69% to 100.65±1.48%. The results were compared with that of the reported method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Application of smart spectrophotometric methods and artificial neural network for the simultaneous quantitation of olmesartan medoxamil, amlodipine besylate and hydrochlorothiazide in their combined pharmaceutical dosage form

BACKGROUND New, simple and specific spectrophotometric methods and artificial neural network (ANN) were developed and validated in accordance with ICH guidelines for the simultaneous estimation of Olmesartan (OLM), Amlodipine (AML), and Hydrochlorothiazide (HCT) in commercial tablets. RESULTS For spectrophotometric methods: First, Amlodipine (AML) was determined by direct spectrophotometry at...

متن کامل

Three Multivariate Calibration Methods for Simultaneous Spectrophotometric Determination of Olmesartan Medoxamil, Amlodipine Besylate and Hydrochlorothiazide in Their Combined Dosage Form

Olmesartan medoxamil (OLM, an angiotensin II receptor blocker), amlodipine besylate (AML, a dihydropyridine calcium channel blocker) and hydrochlorothiazide (HCT, a diuretic of the class of benzothiadiazines) are co-formulated in a single-dose combination for the treatment of hypertensive patients whose blood pressure is not adequately controlled on either component monotherapy. In this work, t...

متن کامل

Spectrophotometric and High Performance Liquid Chromatographic Determination of Amlodipine Besylate in Pharmaceuticals

Two rapid assay procedures based on visible spectrophotometry and high performance liquid chromatography (HPLC) have been developed for the determination of amlodipine besylate (ADB) in pharmaceutical formulations. Spectrophotometric method is based on the bromination of ADB with a known excess of bromate-bromide mixture in acid medium followed by the determination of surplus bromine by reactin...

متن کامل

Simultaneous Estimation of Telmisartan and Amlodipine Besylate in Pharmaceutical Dosage Form by Rp – Hplc

The chromatographic analysis was performed on ODS symmetry C18 column (150 × 4.6 mm, 5 μ particle size) with mobile phase consisting of acetonitrile and phosphate buffer (pH 4.0) in the ratio of 60:40 v/v, at a flow rate of 1.2 mL/min and eluents monitored at 237 nm. The method was validated for linearity, accuracy, precision, robustness and application for assay as per International Conference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012