Anteroposterior glide versus rotating platform low contact stress (LCS) knee arthroplasty: a randomised controlled trial

نویسندگان

  • Gayle Walley
  • Sandeep Datir
  • Murali Sayana
  • Aziz Rahmatalla
  • Ian Dos Remedios
  • Charles Wynn-Jones
  • Stephen Bridgman
  • Nicola Maffulli
چکیده

BACKGROUND Fifty thousand knee replacements are performed annually in the UK at an estimated cost of pound 150 million. Post-operative improvement depends on a number of factors including implant design and patient associated factors. To our knowledge there are no published study's comparing the results of AP glide and rotating platform designs of LCS knee arthroplasty. Therefore we feel that a study is required to investigate and compare the effects of two types of LCS total knee arthroplasty on joint proprioception and range of motion. METHODS/DESIGN Patients will be randomised to receive either a LCS AP glide or Rotating platform prosthesis. Clinical scores (Oxford knee score, American knee society score, EuroQol), range of motion and proprioception will be assessed prior to and at 3,6, 12 and 24 months after the operation. Proprioception will be assessed in terms of absolute error angle (mean difference between the target angle and the response angle). Knee angles will be measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak that detects positions of sensors placed on the test limb. Student's t-test will be used to compare the mean of two groups. DISCUSSION Evidence is lacking concerning the best prosthesis to use for patients undergoing total knee replacement. This pragmatic randomised trial will test the null hypothesis that anteroposterior glide LCS knee arthroplasty does not result in better post operative knee motion and proprioception as compared to rotating platform LCS knee.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early results of total knee arthroplasty with a low contact stress anteroposterior glide.

PURPOSE To present early results of 400 consecutive low contact stress (LCS) anteroposterior (AP) glide total knee arthroplasties (TKAs) performed by a single surgeon. METHODS 304 consecutive patients aged 30 to 96 (mean, 66) years underwent 400 TKAs using LCS AP glides performed by a single surgeon. Only patients with an intact posterior cruciate ligament, a fixed flexion deformity of <15 de...

متن کامل

Comparison of the Clinical Outcomes after Total Knee Arthroplasty with the LCS Rotating Platform Mobile Bearing Knee System and the PFC Sigma RP-F Mobile Bearing Knee System

BACKGROUND We compared clinical outcomes after total knee arthroplasty with the Low Contact Stress (LCS) rotating platform mobile bearing knee system and the Press Fit Condylar Sigma rotating platform high flexion (PFC Sigma RP-F) mobile bearing knee system. METHODS Fifty cases of total knee arthroplasty were performed with the PFC Sigma RP-F mobile bearing knee system and sixty-one cases wer...

متن کامل

A Comparison of the Clinical and Radiographic Results of Press Fit Condylar Rotating-Platform High-Flexion and Low Contact Stress Mobile Bearing Prosthesis in Total Knee Arthroplasty: Short term Results

PURPOSE This study compared the results of rotating-platform high-flexion (RP-F) total knee arthroplasty with low contact stress (LCS) for clinical and radiographical assessment after a short-term period. MATERIALS AND METHODS 68 total knee arthroplasties using a RP-F and LCS system were analyzed retrospectively. Thirty-five of the 68 were osteoarthritic knees and were followed-up for more th...

متن کامل

Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition

PURPOSE To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. MATERIALS AND METHODS From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included...

متن کامل

Long-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs.

PURPOSE to evaluate the differences in clinical outcome and survivorship of three different mobile bearings for total knee arthroplasty. METHODS a retrospective study was conducted in 60 patients (53 females, 7 males, mean age: 68 years and 5 months) each submitted to total knee replacement using one of the three different mobile bearings of the LCS system (Depuy Johnson & Johnson, Warsaw, IN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Musculoskeletal Disorders

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2007