Probabilistic Evaluation of Three-Dimensional Reconstructions from X-Ray Images Spanning a Limited Angle
نویسندگان
چکیده
An important part of computed tomography is the calculation of a three-dimensional reconstruction of an object from series of X-ray images. Unfortunately, some applications do not provide sufficient X-ray images. Then, the reconstructed objects no longer truly represent the original. Inside of the volumes, the accuracy seems to vary unpredictably. In this paper, we introduce a novel method to evaluate any reconstruction, voxel by voxel. The evaluation is based on a sophisticated probabilistic handling of the measured X-rays, as well as the inclusion of a priori knowledge about the materials that the object receiving the X-ray examination consists of. For each voxel, the proposed method outputs a numerical value that represents the probability of existence of a predefined material at the position of the voxel while doing X-ray. Such a probabilistic quality measure was lacking so far. In our experiment, false reconstructed areas get detected by their low probability. In exact reconstructed areas, a high probability predominates. Receiver Operating Characteristics not only confirm the reliability of our quality measure but also demonstrate that existing methods are less suitable for evaluating a reconstruction.
منابع مشابه
Comparison of Reformatted Two-Dimensional Images with Three-Dimensional Reconstructions Based on Images from Multi-Detector Computed Tomography of the Temporal Bone in Surgical Candidates of Chronic Otitis Media Patients
of the auditory ossicles in chronic otitis media patients. Materials and Methods: This study was carried out in 30 ears with chronic otitis media. All cases underwent an axial multidetector computed tomography imaging study. In addition to the axial images, sagittal and coronal multiplanar two-dimensional reformations and three-dimensional reconstructions were generated. Auditory ossicles were ...
متن کاملEvaluation of cephalometric landmark identification on CBCT multiplanar and 3D reconstructions.
OBJECTIVE To evaluate the reliability of three-dimensional (3D) landmark identification in cone-beam computed tomography (CBCT) using two different visualization techniques. MATERIALS AND METHODS Twelve CBCT images were randomly selected. Three observers independently repeated three times the identification of 30 landmarks using 3D reconstructions and 28 landmarks using multiplanar views. The...
متن کاملResidual Fluid Blobs and Contact Angle Measurements from X-ray Images of Fluid Displacement
Over the past decade a growing number of high resolution, three-dimensional, X-ray computed tomography images of multiphase porous media systems have become available, as have the number of algorithms to analyze both the pore space and the fluid partitioning imaged within the voids. Here we consider the measurement of fluid-fluid and fluid-solid surfaces at residual fluid conditions in a Berea ...
متن کاملFootprint as an alternative to X-ray in hallux valgus angle measurement
Background: X- ray images provide accurate and reliable data in different foot pathologies. However, the accompanied complications will limit its use for epidemiological studies and research purposes, especially in children. Therefore, simple, accessible, and cost- effective methods such as footprint, with a good correlation with x-ray images, are needed to help diagnose different foot pa...
متن کاملImage processing methods for limited angle tomography and sparse angle tomography
The purpose of medical computed tomography (CT) is to generate a three dimensional (3D) model of inner organs based on number of two dimensional (2D) X-ray images taken from different directions around the patient. Clinical CT imaging improves and extends the operational and diagnostic X-ray imaging since it basically adds a new spatial dimension to the data by converting multiple 2D images int...
متن کامل