Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems [Corrigendum]

ثبت نشده
چکیده

[This corrects the article on p. 1367 in vol. 9, PMID: 26229430.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems

PURPOSE To compare cumulative dissipated energy between two phacoemulsification machines. SETTING An ambulatory surgical center, Honolulu, Hawaii, USA. DESIGN Retrospective chart review. METHODS A total of 2,077 consecutive cases of cataract extraction by phacoemulsification performed by five surgeons from November 2012 to November 2014 were included in the study; 1,021 consecutive cases ...

متن کامل

Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems

BACKGROUND Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. METHODS Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, ...

متن کامل

Effect of IOP based infusion system with and without balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification

BACKGROUND To evaluate the effect of three different combinations of tip designs and infusion systems in torsional phacoemulsification (INFINITI and CENTURION) in patients with cataract. According to the manufacturer, two unique improvements in the Centurion are: active fluid dynamic management system and use of an intrepid balanced tip. The study specifically aimed to evaluate the beneficial e...

متن کامل

A retrospective randomized study to compare the energy delivered using CDE with different techniques and OZil® settings by different surgeons in phacoemulsification

Cumulative dissipated energy (CDE) was used with Infiniti((R)) Vision System (Alcon Labs) as an energy delivery guide to compare four different phaco techniques and phaco settings. The supracapsular phaco technique and burst mode is known for efficiency and surgery is faster compared with the old phaco unit. In this study, we found that supracapsular phaco with burst mode had the least CDE in b...

متن کامل

Efficacy of Torsional Phaco in Hard Egyptian Cataract Versus Combined Torsional and Longitudinal Phaco Using the Infiniti Vision System

Purpose: To compare the efficacy and phacoemulsification parameters of torsional mode versus the combined torsional and longitudinal ultrasound mode in hard cataract of Egyptian patients. Methods: This randomized comparative study evaluated eyes 1, 7, and 30 days after phacoemulsification with an Infiniti Vision System using the torsional mode versus the combined torsional (100%) and longitudin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015