Complications of the Screw/washer Tibial Fixation Technique for Knee Ligament Reconstruction

نویسندگان

  • Alexandre Almeida
  • Gilberto Roveda
  • Márcio Rangel Valin
  • Nayvaldo Couto de Almeida
  • Vanderlei Sartor
  • Soraya Melina Alves
چکیده

UNLABELLED To evaluate the presence of pain at the site of the surgical incision and the need to remove the tibial fixation screw in anterior cruciate ligament (ACL) reconstruction, in relation to sex and body mass index (BMI). METHODS A group of 265 patients who underwent ACL reconstruction with ipsilateral flexor tendon grafts from the thigh in which the tibial fixation technique consisted of using a cortical screw and metal washer, between July 2000 and November 2007, were evaluated. RESULTS 176 patients were evaluated for an average of 33.3 ± 19.5 months; median of 29.5 months; IIQ: 17-45 months; minimum of 8 and maximum of 87 months. There was no statistical difference regarding complaints of pain at the site of the screw (p = 0.272) and the need to remove the tibial screw (p = 0.633) between sexes. There was no statistical difference regarding complaints of pain at the site of the screw (p = 0.08) and the need to remove the tibial screw (p = 0.379) according to BMI. CONCLUSION The pain complaint rate at the screw site from the screw and metal washer method used for tibial fixation in ACL reconstruction was of the order of 25%, and the screw had to be removed in 10.8% of the cases. There was no predominance of pain complaints at the surgical wound between the sexes. There was a greater tendency to complain about pain among patients with BMI < 25. There was no predominance of screw and washer removal between the sexes or between individuals with different BMIs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

BACKGROUND The tensile force applied to an anterior cruciate ligament graft determines the maximal anterior translation; however, it is unknown whether the tensile force is transferred to the intra-articular portion of the graft and whether the intra-articular tension and maximal anterior translation are maintained shortly after ligament reconstruction. METHODS Ten cadaveric knees were recons...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

بازسازی رباط متقاطع قدامی زانو با استفاده از رباطهای هام استرینگ و ثابت کننده پیچ و واشر خاردار

 Fifty consecutive patients with ACL deficiency and inability to do sports and daily activities underwent endoscopic ACL reconstruction with a four strands of hamstring tendon. After completion of a brace free, intensive rehabilitaion in a prospective study we analysed the results.  The graft was placed arthroscopically without impingement by the intercondylar roof and was fixed within the tibi...

متن کامل

reviSiOn anTeriOr cruciaTe ligaMenT recOnSTrucTiOn - dealing WiTh an enlarged Tibial Tunnel

INTRODUCTION Reconstructing a torn anterior cruciate ligament (ACL) in a knee that has had prior ACL surgery presents challenges, especially if multiple procedures have been done in the past. Revision ACL surgery will continue to become more common as the number of primary ACL reconstruction procedures continues to increase. A common problem faced by the surgeon in the revision setting is an en...

متن کامل

The WasherLoc and Bone Dowel: A Rigid, Slippage-Resistant Tibial Fixation Device for a Soft Tissue Anterior Cruciate Ligament Graft

The WasherLoc is a tibial fixation device for soft tissue anterior cruciate ligament (ACL) reconstruction that combines superior fixation properties (945 N strength, 507 N/mm stiffness, and high resistance to slippage) with a simple surgical technique. The WasherLoc is a washer with 13 short spikes that penetrate the soft tissue ACL graft in multiple locations and 4 long peripheral spikes that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2010