Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

نویسندگان

  • H Zaidi
  • M Diaz-Gomez
  • A Boudraa
  • D O Slosman
چکیده

Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on the fuzzy C-means (FCM) algorithm, the method segments the PET transmission images into a given number of clusters to extract specific areas of differing attenuation such as air, the lungs and soft tissue, preceded by a median filtering procedure. The reconstructed transmission image voxels are, therefore, segmented into populations of uniform attenuation based on knowledge of the human anatomy. The clustering procedure starts with an overspecified number of clusters followed by a merging process to group clusters with similar properties (redundant clusters) and removal of some undesired substructures using anatomical knowledge. The method is unsupervised, adaptive and allows the classification of both pre- or post-injection transmission images obtained using either coincident 68Ge or single-photon 137Cs sources into main tissue components in terms of attenuation coefficients. A high-quality transmission image of the scanner bed is obtained from a high statistics scan and added to the transmission image. The segmented transmission images are then forward projected to generate attenuation correction factors to be used for the reconstruction of the corresponding emission scan. The technique has been tested on a chest phantom simulating the lungs, heart cavity and the spine, the Rando-Alderson phantom, and whole-body clinical PET studies showing a remarkable improvement in image quality, a clear reduction of noise propagation from transmission into emission data allowing for reduction of transmission scan duration. There was very good correlation (R2 = 0.96) between maximum standardized uptake values (SUVs) in lung nodules measured on images reconstructed with measured and segmented attenuation correction with a statistically significant decrease in SUV (17.03% +/- 8.4%, P < 0.01) on the latter images, whereas no proof of statistically significant differences on the average SUVs was observed. Finally, the potential of the FCM algorithm as a segmentation method and its limitations as well as other prospective applications of the technique are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuation correction for whole-body PET imaging using automated fuzzy clustering-based segmentatio - Nuclear Science Symposium Conference Record, 2001 IEEE

Segmented-based attenuation correction is now a widely accepted technique to reduce noise contribution of measured attenuation correction. In this paper, we present a new method for segmenting transmission images in positron emission tomography. This reduces the noise on the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on the Fuzzy C-M...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography.

Reliable attenuation correction represents an essential component of the long chain of modules required for the reconstruction of artifact-free, quantitative brain positron emission tomography (PET) images. In this work we demonstrate the proof of principle of segmented magnetic resonance imaging (MRI)-guided attenuation and scatter corrections in three-dimensional (3D) brain PET. We have devel...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

A robust MR-based attenuation map generation in short-TE MR images of the head employing hybrid spatial fuzzy C-means clustering and intensity inhomogeneity correction

Quantitative MR Imaging and Spectroscopy Group, Research Center for Cellular and Molecular Imaging, Tehran University of Medical Sciences, Tehran, Iran Deriving an accurate attenuation correction map (μ-map) from magnetic resonance (MR) volumes has become an important problem in hybrid PET/MR imaging. Recently, short echo-time (STE) MR imaging technique incorporating fuzzy C-means (FCM) tissue ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 7  شماره 

صفحات  -

تاریخ انتشار 2002