Time-Efficient Myocardial Contrast Partition Coefficient Measurement from Early Enhancement with Magnetic Resonance Imaging

نویسندگان

  • Shi-Jun Zhang
  • Yi-Xiang Wang
  • Jing Yuan
  • Jiyang Jin
  • Yuan-Cheng Wang
  • Di Chang
  • Dehe Weng
  • Andreas Greiser
  • Shenghong Ju
چکیده

OBJECTIVE Our purpose was to validate an early enhancement time point for accurately measuring the myocardial contrast partition coefficient (lambda) using dynamic-equilibrium magnetic resonance imaging. MATERIALS AND METHODS The pre- and post-contrast longitudinal relaxation rates (reciprocal of T1) of the interventricular septum (R1(m)) and blood pool (R1(b)) were obtained from fifteen healthy volunteers and three diabetic patients with hypertension using two optimized T1 mapping sequences (modified Look-Locker inversion recovery) on a 3-Tesla magnetic resonance scanner. Reference lambda values were calculated as the slope of the regression line of R1(m) versus R1(b) at dynamic equilibrium (multi-point regression method). The simplified pre-/post-enhancement two-acquisition method (two-point method) was used to calculate lambda by relating the change in R1(m) and R1(b) using different protocols according to the acquisition stage of the post-enhancement data point. The agreement with the referential method was tested by calculating Pearson's correlation coefficient and the intra-class correlation coefficient. RESULTS The lambda values measured by the two-point method increased (from 0.479 ± 0.041 to 0.534 ± 0.043) over time from 6 to 45 minutes after contrast and exhibited good correlation with the reference at each time point (r ≥ 0.875, p<0.05). The intra-class correlation coefficient on absolute agreement with the reference lambda was 0.946, 0.929 and 0.922 at the 6th, 7th and 8th minutes and dropped from 0.878 to 0.403 from the 9th minute on. CONCLUSIONS The time-efficient two-point method at 6-8 minutes after the Gd-DTPA bolus injection exhibited good agreement with the multi-point regression method and can be applied for accurate lambda measurement in normal myocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanism of late gadolinium enhancement in patients with acute myocardial infarction.

PURPOSE To investigate the mechanism of late gadolinium enhancement in irreversibly damaged myocardium in patients with acute myocardial infarct by determining kinetics of Gd-DTPA over time. METHODS Twenty-nine patients (24 men; 64 +/- 9 years) with acute myocardial infarction were imaged with functional and gadolinium enhanced cardiovascular magnetic resonance (CMR) 18 minutes post 0.2 mmol/...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Assessment of diffuse myocardial fibrosis in systemic sclerosis by cardiac magnetic resonance imaging

Background Systemic sclerosis (SSc) is a connective tissue disorder characterized by excessive fibrosis of the skin and internal organs, including the heart. Traditional late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR) imaging is dependent on differential (i.e., focal) fibrosis within the myocardium. However, diffuse interstitial myocardial fibrosis (DF) affecting th...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014