Determination of Reference microRNAs for Relative Quantification in Porcine Tissues

نویسندگان

  • Oriol Timoneda
  • Ingrid Balcells
  • Sarai Córdoba
  • Anna Castelló
  • Armand Sánchez
چکیده

Relative quantification is the strategy of choice for processing RT-qPCR data in microRNAs (miRNAs) expression studies. Normalisation of relative quantification data is performed by using reference genes. In livestock species, such as pigs, the determination of reference miRNAs and the optimal number of them has not been widely studied. In this study, the stability of ten miRNAs (Ssc-let-7a, Ssc-miR-103, Ssc-miR-17-3p, Hsa-miR-25, Hsa-miR-93, Ssc-miR-106a, Ssc-miR-191, Ssc-miR-16, Ssc-miR-26a and Ssc-miR-17-5p) was investigated by RT-qPCR in different tissues (skeletal muscle, kidney, liver, ovary and uterus) and in different pig breeds (Iberian, Landrace, Large White, Meishan and Vietnamese) as variation factors. Stability values were calculated with geNorm and NormFinder algorithms obtaining high correlation between them (r(2) = 0.99). The analyses showed that tissue is an important variability factor in miRNAs expression stability whereas breed is not a determinant factor. All ten miRNAs analysed had good stability values and, therefore, can be used as reference miRNAs. When all tissues were considered, miR-93 was the most stable miRNA. Dividing data set by tissues, let-7a was the most stable in skeletal muscle and ovary, miR-17-5p in kidney, miR-26a in liver and miR-103 in uterus. Moreover, the optimal number of reference miRNAs to be used for proper normalisation data was determined. It is suggested the use of five reference miRNAs (miR-93, miR-25, miR-106a, miR-17-5p and miR-26a) in multi-tissue experimental designs and the use of three reference miRNAs as the optimal number in single tissues studies (let-7a, miR-17-5p and miR-25 in skeletal muscle; miR-17-5p, miR-93 and miR-26a in kidney, miR-26a, miR-103 and let-7a in liver, let-7a, miR-25 and miR-106a in ovary and miR-103, let-7a and miR-93 in uterus). Overall, this study provides valuable information about the porcine reference miRNAs that can be used in order to perform a proper normalisation when relative quantification by RT-qPCR studies is undertaken.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Potential Reference Genes for Relative Quantification by RT-qPCR in Different Porcine Tissues Derived from Feeding Studies

Five potential reference genes for RT-qPCR application, namely histone H3, beta-actin, GAPDH, ubiquitin and 18S rRNA, were evaluated for normalization of gene expression in four selected tissues (liver, kidney, thyroid and abdominal fat). Tissues were derived from fattening pigs exposed to different amounts and type of dietary iodine. Two software applications (geNorm and NormFinder) were used ...

متن کامل

Extraction sorbent with octadecane-functionalized nano graphene for the preconcentration of Cu(II) in water and tissues from liver loggerhead turtles specimens

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples was reported. In this paper, Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (IIDE) in order to prepare an effective sorbent for the preconcentration and determination of Cu. The sorption capacity of Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (II...

متن کامل

Extraction sorbent with octadecane-functionalized nano graphene for the preconcentration of Cu(II) in water and tissues from liver loggerhead turtles specimens

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples was reported. In this paper, Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (IIDE) in order to prepare an effective sorbent for the preconcentration and determination of Cu. The sorption capacity of Isopropyl 2-[(isopropoxy carbothioyl)disulfanyl]ethanethioate (II...

متن کامل

Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods

Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...

متن کامل

Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods

Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012