The role of pulse oximetry in the accident and emergency department.

نویسندگان

  • M A Lambert
  • J Crinnion
چکیده

Prompt recognition and treatment of hypoxia is an important part of management in the accident and emergency (A & E) department. Until recently the only reliable method of detecting hypoxia was by estimation of the arterial blood gases (ABG). Continuous monitoring of the arterial oxygen saturation (Sao2) is possible using an infra-red pulse oximeter. This study assessed the usefulness of this instrument in the A&E setting. The Sao2 was measured in 50 patients using a pulse oximeter. In 15 patients simultaneous ABG estimations were obtained. The Sao2 correlated closely with calculated values for Sao2. The use of the oximeter identified 21 patients (42%) with clinically unsuspected hypoxia. The pulse oximeter proved simple to use, accurate and a useful addition to our resuscitation equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Cerebral oximetry and stroke distance: the future of emergency department monitoring?

OBJECTIVE To illustrate the possible role of cerebral oximetry and stroke distance as measured by Doppler ultrasound in monitoring the critically ill patient non-invasively in the emergency department. METHODS Five critically ill patients were monitored with either cerebral oximetry or both cerebral oximetry and stroke distance (the distance travelled by blood in the aorta with each ventricul...

متن کامل

Pulse oximetry in the accident and emergency department.

The early detection and treatment of hypoxia is important to reduce patient morbidity in the accident and emergency department. At present, the commonly used methods all have practical difficulties in the urgent situations that prevail in the department. Pulse oximetry has recently become a method of choice in many anaesthetic and intensive care units for the continuous monitoring of oxygenatio...

متن کامل

Oxygen saturation in adults with acute asthma.

Avoidable deaths from asthma continue. Some of these result from the difficulty in determining the severity of an acute asthma attack at the initial assessment. This study evaluated the relation of pulse oximetry with other markers of severity in 46 patients attending an accident and emergency (A&E) department with acute asthma. Neither oxygen saturation nor peak flow correlated with length of ...

متن کامل

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of emergency medicine

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 1989