New technique for aortic valve functional annulus reshaping using a handmade prosthetic ring.

نویسندگان

  • Khalil Fattouch
  • Roberta Sampognaro
  • Giuseppe Speziale
  • Giovanni Ruvolo
چکیده

BACKGROUND Despite a wide development in aortic leaflets repair techniques, aortic valve annuloplastic procedures are still poorly investigated. We present our aortic valve annuloplastic system consisting of a handmade prosthetic ring with 2 components for reshaping the aortic annulus and sinotubular junction (STJ) and illustrates our surgical approach and clinical results. METHODS Since February 2003, 45 patients with aortic valve regurgitation underwent aortic annuloplasty using the new ring. Mean patient age was 58 ± 16 years (range, 46 to 76 years). The ring has 2 components: a circular ring used to undersize the circumference of the aortoventricular junction and 3-crown-like shape ring used for STJ remodeling. The circular ring was sutured into the left ventricular outflow tract in the aortic subvalvular position and the STJ ring was sutured from the outside of the aortic root just at the level of the STJ. The 3 vertical bands of the STJ ring were fixed to the underlying circular ring to stabilize the continuity between the STJ and nadir of the aortic valve. RESULTS No in-hospital death occurred. Two patients had residual trivial aortic valve regurgitation postoperatively, and 3 patients required treatment for residual aortic regurgitation (more than mild). Mean length of the coaptation surface was 10 ± 2 mm. The mean clinical follow-up (100% complete) was 22 ± 16 months. All patients were free from cardiac and valve-related events, and no complications due to ring implantation occurred. CONCLUSIONS This ring reshapes the functional aortic annulus and stabilizes all components of the native aortic valve stent to improve long-term results of valve repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic prosthetic ring annuloplasty: a useful adjunct to a standardized aortic valve-sparing procedure?

OBJECTIVE Dilation of aortic annulus, sinuses of Valsalva, and sinotubular junction (STJ) diameters are the characteristic lesions of aortic root aneurysm. The remodeling technique reduces STJ diameter and creates three neosinuses of Valsalva. Alternatively, the reimplantation technique reduces both annulus and STJ diameters to the detriment of aortic root dynamics. Although the remodeling tech...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

Off-pump positioning of a conventional aortic valve prosthesis through the left ventricular apex with the universal cardiac introducer under sole ultrasound guidance, in the pig.

OBJECTIVE : To test an alternative to catheter and open-heart techniques, by documenting the feasibility of implanting an unmodified mechanical aortic valve (AoV) in the off pump, beating heart using the universal cardiac introducer (UCI) attached to the left ventricular (LV) apex. METHODS : In six pigs, the LV apex was exposed by a median sternotomy. The UCI was attached to the apex. A 12-mm...

متن کامل

Prosthetic Ring Endocarditis with Shrunken Mitral Annulus Late After Undersized Mitral Annuloplasty

We report a case of supra-annular mitral valve replacement for a patient with prosthetic ring endocarditis that developed late after undergoing undersized mitral annuloplasty (UMAP). A 58year-old man had undergone left ventriculoplasty and UMAP with a 26-mm semi-rigid full ring for dilated cardiomyopathy and functional mitral regurgitation. The mitral valve had progressively stenosed and he dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 91 4  شماره 

صفحات  -

تاریخ انتشار 2011