Acute and chronic effects of epicardial radiofrequency applications delivered on epicardial coronary arteries.

نویسندگان

  • Juan F Viles-Gonzalez
  • Reynaldo de Castro Miranda
  • Mauricio Scanavacca
  • Eduardo Sosa
  • Andre d'Avila
چکیده

BACKGROUND Epicardial coronary injury is by far the most feared complication of epicardial ablation. Little information is available regarding the chronic effects of delivering radiofrequency in the vicinity of large coronary vessels, and the long-term impact of this approach for mapping and ablation on epicardial vessel integrity is poorly understood. Therefore, the aim of this study was to characterize the acute and chronic histopathologic changes produced by in vivo epicardial pulses of radiofrequency ablation on coronary artery of porcine hearts. METHODS AND RESULTS Seven pigs underwent a left thoracotomy. The catheter was sutured adjacent to the left anterior descending artery and left circumflex artery, and 20 pulses of radiofrequency energy were applied. Radiofrequency lesions located no more than 1 mm of the vessel were used for this analysis. Three animals were euthanized 20 days (acute phase) after the procedure and 4 animals after 70 days (chronic phase). The following parameters were obtained in each vessel analyzed: (1) internal and external perimeter; (2) vessel wall thickness; (3) tunica media thickness, and (4) tunica intima thickness. The presence of adipose tissue around the coronary arteries, the distance between the artery and the epicardium, and the anatomic relationship of the artery with the coronary vein was also documented for each section. Sixteen of 20 (80%) sections analyzed, showed intimal thickening with a mean of 0.18 ± 0.14 mm compared with 0.13 ± 0.16 mm in the acute phase (P = 0.331). The mean tunica media thickness was 0.25 ± 0.10 mm in the chronic phase animals compared with 0.18 ± 0.03 mm in the acute phase animals (P = 0.021). A clear protective effect of pericardial fat and coronary veins was also present. A positive correlation between depth of radiofrequency lesion and the degree of vessel injury expressed as intimal and media thickening (P = 0.001) was present. A negative correlation was identified (r = -0.83; P = 0.002) between intimal thickening and distance between epicardium and coronary artery. CONCLUSIONS In this porcine model of in vivo epicardial radiofrequency ablation in proximity to coronary arteries leads to acute and chronic histopathologic changes characterized by tunica intima and media thickening, with replacement of smooth muscle cells with extracellular matrix, but no significant stenosis was observed up to 70 days after the ablation. The absence of acute coronary occlusion or injury does not preclude subsequent significant arterial damage, which frequently occurs when epicardial radiofrequency applications are delivered in close vicinity to the vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Epicardial Adipose Tissue as a New Indicator of Cardiovascular Risk

Abstract Background and Purpose: Epicardial fat is the true visceral fat located around the heart, particularly around sub-epicardial coronary arteries that may locally interact and modulate the coronary arteries and myocardium through paracrine or vasocrine secretion of anti-inflammatory and proatherogenic cytokines. Most previous studies have used echocardiography and reported controversia...

متن کامل

Epicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model.

BACKGROUND Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, ...

متن کامل

Safety and feasibility of closed chest epicardial catheter ablation using electroporation.

BACKGROUND Permanent coronary artery damage is a hazardous complication of epicardial radiofrequency ablation. Irreversible electroporation (IRE) is a promising nonthermal ablation modality able to create deep myocardial lesions. We investigated the effects of epicardial IRE on luminal coronary artery diameter and lesion depth. METHODS AND RESULTS In 5 pigs (60-75 kg), the pericardium was exp...

متن کامل

Epicardial Radiofrequency Ablation Failure During Ablation Procedures for Ventricular Arrhythmias: Reasons and Implications for Outcomes.

BACKGROUND Radiofrequency ablation (RFA) from the epicardial space for ventricular arrhythmias is limited or impossible in some cases. Reasons for epicardial ablation failure and the effect on outcome have not been systematically analyzed. METHODS AND RESULTS We assessed reasons for epicardial RFA failure relative to the anatomic target area and the type of heart disease and assessed the effe...

متن کامل

Phasic coronary blood flow velocity in intramural and epicardial coronary arteries.

Knowledge concerning phasic coronary blood flow is based primarily on measurements obtained from epicardial coronary arteries, which, in part, function as capacitors. If present, epicardial capacitance effects could obscure the dynamic nature of phasic intramyocardial perfusion. To analyze this effect of epicardial capacitance, we simultaneously measured coronary blood flow velocity in an epica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 4 4  شماره 

صفحات  -