Progressive Calibration and Averaging for Tandem Mass Spectrometry Statistical Confidence Estimation: Why Settle for a Single Decoy?

نویسندگان

  • Uri Keich
  • William Stafford Noble
چکیده

Estimating the false discovery rate (FDR) among a list of tandem mass spectrum identifications is mostly done through target-decoy competition (TDC). Here we offer two new methods that can use an arbitrarily small number of additional randomly drawn decoy databases to improve TDC. Specifically, "Partial Calibration" utilizes a new meta-scoring scheme that allows us to gradually benefit from the increase in the number of identifications calibration yields and "Averaged TDC" (a-TDC) reduces the liberal bias of TDC for small FDR values and its variability throughout. Combining a-TDC with "Progressive Calibration" (PC), which attempts to find the "right" number of decoys required for calibration we see substantial impact in real datasets: when analyzing the Plasmodium falciparum data it typically yields almost the entire 17% increase in discoveries that "full calibration" yields (at FDR level 0.05) using 60 times fewer decoys. Our methods are further validated using a novel realistic simulation scheme and importantly, they apply more generally to the problem of controlling the FDR among discoveries from searching an incomplete database.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Statistical validation of peptide identifications in large-scale proteomics using the target-decoy database search strategy and flexible mixture modeling.

Reliable statistical validation of peptide and protein identifications is a top priority in large-scale mass spectrometry based proteomics. PeptideProphet is one of the computational tools commonly used for assessing the statistical confidence in peptide assignments to tandem mass spectra obtained using database search programs such as SEQUEST, MASCOT, or X! TANDEM. We present two flexible meth...

متن کامل

A Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers

An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Research in computational molecular biology : ... Annual International Conference, RECOMB ... : proceedings. RECOMB

دوره 10229  شماره 

صفحات  -

تاریخ انتشار 2017