Detection of moving capillary front in porous rocks using X-ray and ultrasonic methods
نویسندگان
چکیده
Several methods are compared for the detection of moving capillary fronts in spontaneous imbibition experiments where water invades dry porous rocks. These methods are: (i) the continuous monitoring of the mass increase during imbibition, (ii) the imaging of the water front motion using X-ray CT scanning, (iii) the use of ultrasonic measurements allowing the detection of velocity, amplitude and spectral content of the propagating elastic waves, and (iv) the combined use of X-ray CT scanning and ultrasonic monitoring. It is shown that the properties of capillary fronts depend on the heterogeneity of the rocks, and that the information derived from each method on the dynamics of capillary motion can be significantly different. One important result from the direct comparison of the moving capillary front position and the P wave attributes is that the wave amplitude is strongly impacted before the capillary front reaches the sensors, in contrast with the velocity change which is concomitant with the fluid front arrival in the sensors plane.
منابع مشابه
Study of Two Phase Fluid Flow in Water Wet Reservoir Rocks by Using X-Ray In situ Saturation Monitoring
Displacement of oil and water in porous media of reservoir rocks is described by relative permeability curves, which are important input data for reservoir performance simulation and drive mechanism studies. Many core studies, such as multiphase relative permeability, capillary pressure and saturation exponent determination, depend on the volume fractions of multiphase flui...
متن کاملX-Ray in-situ saturation monitoring, an aid to study relative permeability in water-wet carbonate rocks
The simultaneous flow of oil and water in porous media is described by relative permeability curves, mainly derived from laboratory experiments. Relative permeability is of paramount importance in predicting reservoir production performance and drive mechanisms and its value depends largely on the volume fraction of fluids present in the test samples. Nowadays X-ray scanners are one of the most...
متن کاملAccuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites
The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...
متن کاملCapillary trapping in sandstones and carbonates: Dependence on pore structure
[1] Residual non-wetting phase saturation and wetting-phase permeability were measured in three limestones and four sandstones ranging in porosity from 0.13 to 0.28 and in absolute permeability from 2 10 15 to 3 10 12 m. This paper focuses on the residual state established by waterflooding at low capillary number from minimum water saturation achieved using the porous plate technique, which yie...
متن کاملAn Estimation of Wave Attenuation Factor in Ultrasonic Assisted Gravity Drainage Process
It has been proved that ultrasonic energy can considerably increase the amount of oil recovery in an immiscible displacement process. Although many studies have been performed on investigating the roles of ultrasonic waves, based on the best of our knowledge, little attention has been paid to evaluate wave attenuation parameter, which is an important parameter in the determination of the energy...
متن کامل