Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images [7624-121]

نویسندگان

  • Yuji Hatanaka
  • Atsushi Noudo
  • Chisako Muramatsu
  • Akira Sawada
  • Takeshi Hara
  • Tetsuya Yamamoto
  • Hiroshi Fujita
چکیده

Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Automatic Image Processing System for Glaucoma Screening

Horizontal and vertical cup to disc ratios are the most crucial parameters used clinically to detect glaucoma or monitor its progress and are manually evaluated from retinal fundus images of the optic nerve head. Due to the rarity of the glaucoma experts as well as the increasing in glaucoma's population, an automatically calculated horizontal and vertical cup to disc ratios (HCDR and VCDR, res...

متن کامل

An Efficacious Method of Cup to Disc Ratio Calculation for Glaucoma Diagnosis Using Super pixel

Glaucoma is a chronic eye disease that leads to vision loss. Since it cannot be cured, detecting the disease in time is important. The tests which are done to detect Glaucoma using intraocular pressure (IOP) are not sensitive enough for population based glaucoma screening. The assessment of Optic nerve head damage in retinal fundus images is both more promising and superior. In this paper the o...

متن کامل

Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relev...

متن کامل

Optic Disc and Cup Segmentation for glaucoma Screening based on Superpixel classification

Glaucoma is a chronic eye disease that leads to blindness. This disease cannot be cured but we can detect the disease in time. Current tests using intraocular pressure (IOP) measurement are not sensitive enough for population based glaucoma screening. Optic nerve head assessment in retinal fundus images is more promising and superior than current methods. This paper proposes segmentation of opt...

متن کامل

Techniques of Glaucoma Detection From Color Fundus Images: A Review

Glaucoma is a generic name for a group of diseases which causes progressive optic neuropathy and vision loss due to degeneration of the optic nerves. Optic nerve cells act as transducer and convert light signal entered into the eye to electrical signal for visual processing in the brain. The main risk factors of glaucoma are elevated intraocular pressure exerted by aqueous humour, family histor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010