Fuzzy-Logic Applications in Transformer Diagnosis Using Individual and Total Dissolved Key Gas Concentrations

نویسندگان

  • Hasmat Malik
  • R. K. Jarial
  • H. M. Rai
چکیده

The gases generated in oil filled transformer can be used for determination of incipient faults. Dissolved gas analysis (DGA) of transformer oil has been one of the most power full methods to detect the faults. The various methods such as liquid chromatography, acoustic analysis, and transformer function techniques are require some experience to interpret observations. The researchers have used artificial intelligence (AI) approach to encode these diagnostic techniques. This paper presents an expert system using AI techniques which can diagnose multiple faults in a transformer theoretical and practical fuzzy-logic information model. We also concluded by identifying limitations, recent advances and promising future research directions over seventy and more power transformers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Fuzzy Logic in Fault Diagnosis in Transformers using Dissolved Gas based on Different Standards

One of the problems in fault diagnosis of transformer based on dissolved gas, is lack of matching the result of fault diagnosis of different standards with the real world. In this paper, the result of the different standards is analyzed using fuzzy and the result is compared with the empirical test. The comparison between the suggested method and existing methods indicate the capability of the ...

متن کامل

Intuitionistic Fuzzy Expert System based Fault Diagnosis using Dissolved Gas Analysis for Power Transformer

In transformer fault diagnosis, dissolved gas analysis (DGA) is been widely employed for a long period and numerous methods have been innovated to interpret its results. Still in some cases it fails to identify the corresponding faults. Due to the limitation of training data and non-linearity, the estimation of key-gas ratio in the transformer oil becomes more complicated. This paper presents I...

متن کامل

Fuzzy Decision on Transformer Fault Diagnosis using Dissolved Gas Analysis and IEC Ratio Codes

This paper emphasizes on the use of fuzzy approach in dealing with the incipient fault conditions of power transformer. DGA (Dissolved Gas in Oil Analysis) cannot provide better fault diagnosis results when multiple faults are involved. The boundary values specified by the ratio methods are of limited concern .Considering the limitations of convergence of the conventional neural networks in the...

متن کامل

Analysis of Power Transformer using fuzzy expert and neural network system

Power transformers being the major apparatus in a power system, thus the assessment of transformer operating condition and lifespan have obtained crucial significance in latest years. Dissolved gas analysis (DGA) is a sensitive and reliable technique for the detection of incipient fault condition within oil-immersed transformers, which provides the basis of diagnostic evaluation of equipment he...

متن کامل

Diagnosis of Power Transformer Faults based on Five Fuzzy Ratio Method

Dissolved Gas Analysis is one of the most useful method to detect incipient faults in transformer. Amongst the conventional DGA methods, IEC three ratio method is widely used. One of the disadvantages in its present form is that a significant number of DGA results inservice fall outside the existing IEC codes and cannot be diagnosed. To overcome this limitation, additional eighteen new combinat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012