Intrauterine levonorgestrel delivery with frameless fibrous delivery system: review of clinical experience

نویسندگان

  • Dirk Wildemeersch
  • Amaury Andrade
  • Norman D Goldstuck
  • Thomas Hasskamp
  • Geert Jackers
چکیده

The concept of using a frameless intrauterine device (IUD) instead of the conventional plastic framed IUD is not new. Frameless copper IUDs have been available since the late 1990s. They rely on an anchoring system to retain in the uterine cavity. The clinical experience with these IUDs suggests that frameless IUDs fit better as they are thin and, therefore, do not disturb or irritate the uterus. High tolerance and continuation rates have been achieved as complaints of pain are virtually nonexistent and the impact on menstrual blood loss is minimal. Conventional levonorgestrel-releasing intrauterine systems (LNG-IUSs) are very popular as they significantly reduce menstrual bleeding and provide highly effective contraception. However, continuation of use remains problematic, particularly in young users. Total or partial expulsion and displacement of the LNG-IUS also occur too often due to spatial incompatibility within a small uterine cavity, as strong uterine contractions originate, attempting to get rid of the bothersome IUD/IUS. If not expelled, embedment ensues, often leading to chronic pain and early removal of the IUD/IUS. Several studies conducted recently have requested attention to the relationship between the LNG-IUS and the endometrial cavity. Some authors have proposed to measure the cavity width prior to inserting an IUD, as many uterine cavities are much smaller than the currently existing LNG-IUSs. A frameless fibrous drug delivery system fits, in principle, in all uterine cavities and may therefore be preferable to framed drug delivery systems. This review examines the clinical performance, acceptability, and potential of the frameless LNG-IUS (FibroPlant®) when used for contraception, treatment of heavy menstrual bleeding, dysmenorrhea, and endometrial suppression in women using estrogen replacement therapy, endometrial hyperplasia, and other gynecological conditions. The review concludes that FibroPlant LNG-IUS offers unique advantages in reducing side effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study

BACKGROUND The purpose of this study was to provide additional data on the experience with frameless copper and levonorgestrel (LNG) intrauterine devices (IUDs) in nulliparous and adolescent women. METHODS Nulliparous and adolescent women, 25 years of age or younger, using the frameless copper IUD or the frameless LNG-releasing intrauterine system (IUS), were selected from previous studies an...

متن کامل

Precision intrauterine contraception may significantly increase continuation of use: a review of long-term clinical experience with frameless copper-releasing intrauterine contraception devices

OBJECTIVE The purpose of this paper is to review the experience with the frameless, anchored, GyneFix copper-releasing intrauterine contraceptive devices (IUCDs/IUDs) (Contrel Europe, Belgium), and to demonstrate their high acceptability and low rate of discontinuation of use, which could contribute to current efforts that aim to reduce radically the high number of unintended pregnancies and in...

متن کامل

Morphological and functional features of endometrial decidualization following long-term intrauterine levonorgestrel delivery.

Irregular bleeding remains a common reason for the discontinuation of progestin-only contraception. The levonorgestrel releasing intrauterine system (LNG-IUS) has profound morphological effects upon the endometrium. Specific features are gland atrophy and extensive decidual transformation of the stroma. Morphological changes in the endometrium may be associated with perturbation of mechanisms r...

متن کامل

Assessment of menstrual blood loss in Belgian users of the frameless copper-releasing IUD with copper surface area of 200 mm2 and users of a copper-levonorgestrel-releasing intrauterine system.

OBJECTIVE This study was conducted to evaluate the effect of a miniaturized frameless copper IUD (GyneFix 200 small) and a copper-levonorgestrel (GynePlant) intrauterine system (IUS) on the amount of menstrual blood loss (MBL). METHODS In 60 Belgian women using GyneFix 200 and 21 using GynePlant, MBL was assessed with the visual assessment technique. RESULTS MBL scores in GyneFix 200 users ...

متن کامل

Use of a frameless LNG-IUS as conservative treatment for a pre-malignant uterine polyp in a premenopausal woman – a case report

Prevention of progression to invasive carcinoma in patients with a premalignant endometrial lesion using longterm treatment with levonorgestrel (LNG) releasing intrauterine systems (IUS) remains controversial, especially when manifest cellular atypia has been found in the endometrial biopsy specimen. We present a case of a 44-year old premenopausal woman with a premalignant uterine polyp who de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017